06 functional block diagrams, 07 transporting methods, Arcmaster 300 acdc – Tweco 300 DC Arcmaster User Manual

Page 20

Advertising
background image

ARCMASTER 300 ACDC

2-4

February 22, 2006

2.06 Functional Block Diagrams

Figure 2-2 illustrates the functional block diagram of the 300 ACDC-power supply.

Art # A-04981

Main

Circuit

Switch

Filter

Input

Diode

Primary

Capacitor

DC Power

Voltage

Sensor

IGBT

Inverter

Thermal

Detector

To each control circuit

+/-15VDC +18VDC

+24VDC +5VDC

Trouble

Sensing

Circuit

Drive

Circuit

Torch Control

Connection

(CON1)

circuit

Current

Adjustment

Reference

Adjustment &

Mode select Switches

Panel Circuit Board

Sequence

Control

Th ermal

Sensor

Circuit

Main

Transformer

(PCB14)

Output

Diodes

HF-UNIT

Control

Circuit

Stick Mode

VRD

Sensing

Circuit

Lift Tig Mode
Output Short

Sensing

Circuit

Coupling

High

Coil

Frequency

Unit

Fan Control

Circuit

Gas Control

Circuit

Fan

Solenoid

Hall Current

Transformer

(HCT1)

Output

Inductor

Thermal

Detector

Input

Power

Drive

DC Power

Circuit

To each control circuit

+/-12VDC +15VDC

Secondary

IGBT

Inverter

Primary

Current

Sensor

Figure 2-2: 300 ACDC Model Functional Block Diagram

2.07 Transporting Methods

These units are equipped with a handle for carrying
purposes.

WARNING

ELECTRIC SHOCK can kill. DO NOT TOUCH
live electrical parts. Disconnect input power
conductors from de-energized supply line
before moving the welding power source.

WARNING

FALLING EQUIPMENT can cause serious
personal injury and equipment damage.

• Lift unit with handle on top of case.

• Use handcart or similar device of adequate capacity.

• If using a fork lift vehicle, place and secure unit on a

proper skid before transporting.

Advertising
This manual is related to the following products: