09 specifications, 09 specifications -5, Arcmaster 300 acdc – Tweco 300 DC Arcmaster User Manual

Page 25

Advertising
background image

ARCMASTER 300 ACDC

Februrary 22, 2006

3-5

3.09 Specifications

Parameter

300ACDC

Rated Output

Amperes

300

Volts

22

Duty Cycle

25%

TIG

300A / 22V @ 25% 190A / 17V @
60% 150A / 16V @ 100%

Duty Cycle

STICK

300A / 32V @ 25%

190A / 27V @ 60%

150A / 26V @ 100%

TIG

5 - 300 (DC) 5 - 300 (AC) @
60Hz, 50% Cleaning

Output
Current
Range

STICK

5 - 300 (DC)

5 - 300 (AC) @ 60Hz,

50% Cleaning

Open Circuit Voltage

65V

Dimensions

Width

8.3” (210mm)

Height

16.5” (420mm)

Length

17.7” (450mm)

Weight

52.8 lb. 24 kg

Output @ Rated Load

Rated Input Voltage

Three-phase

Single-phase

Output Amperes

300A

300A

Output Volts

32V

32V

Duty Cycle

25%

25%

KVA

18.0

20.0

KW

12.0

12.0

Output @ No Load

Rated Input Voltage

Three-phase

Single-phase

KVA

0.5

0.5

KW

0.13

0.13

Input Volts Three Phase
208V 230V 460V

Amperage
Draw @ Rated
Load 45 41 21

No Load Amps
1.4 1.3 0.7

Input Volts Single
Phase 208V 230V

Amperage
Draw @ Rated
Load 97 87

No Load Amps
2.5 2.2

Table 3-3: Parameter Specifications

Thermal Arc continuously strives to produce the best
product possible and therefore reserves the right to
change, improve or revise the specifications or design of
this or any product without prior notice. Such updates or
changes do not entitle the buyer of equipment previously
sold or shipped to the corresponding changes, updates,
improvements or replacement of such items.

The values specified in this table are optimal values, your
values may differ. Individual equipment may differ from
the above specifications due to in part, but not exclusively,
to any one or more of the following; variations or changes
in manufactured components, installation location and
conditions and local power grid supply conditions.