Arcmaster 300 acdc – Tweco 300 DC Arcmaster User Manual

Page 38

Advertising
background image

ARCMASTER 300 ACDC

6-2

February 22, 2006

1

8

3

4

6

9

10

2

7

5

Art # A-07656

Figure 6-1b: 300 ACDC Front Panel

1. Pulse Function:

Pressing this button enables the TIG current pulse
functions.

2. Remote Current function:

Pressing this button enables remote current func-
tions.

3. TIG Mode Functions:

Pressing this button scrolls through the output TIG
function modes (Standard, Slope, Slope w/repeat,
Spot).

4. Digital LED Display:

Welding amperage and parameter values are
displayed in this window. Internal warnings such as
over temperature, low or high input voltage applied
are signaled to the operator by a warning sound and
error message on the screen.

5. Save/Load Buttons:

By using the Save & Load buttons the operator can
easily save up to 5 welding parameter programs.

6. Control Knob: Allows the operator to adjust the out-

put amperage within the entire range of the power
source and sets each parameter value.

7. Process Button:

This button selects between STICK, HF TIG and Lift
TIG mode.

8. Scroll Buttons:

Used to select the parameters to be set. The LED's
show which function is being adjusted on the
Sequence Graph.

9. AC/DC Button:

Selects between AC or DC welding output.

10.Contactor Function:

Pressing this button enables Contactor functions.

Advertising