10.03 Power Source Problems

Description

Possible Cause

Remedy

A The Primary supply voltage

has not been switched ON.

A Switch ON the Primary

supply voltage.

B The Welding Power Source

switch is switched OFF.

B Switch ON the Welding

Power Source.

C Loose connections

internally.

C Have an Accredited Thermal

Arc Service Agent repair the
connection

2 Maximum output

welding current can
not be achieved with
nominal Mains supply
voltage.

Defective control circuit.

Have an Accredited Thermal
Arc Service Agent repair the
connection

A Loose welding cable

connections.

A Tighten all welding cable

connections.

B Incorrect welding cable size. B Use proper size and type of

cable.

C Improper input connections. C Refer to Section 2.05

Electrical Input
Requirements.

D Poor electrode condition.

D Replace electrode.

E Wrong welding polarity.

E Verify output torch

connections.

A Gas hose is cut.

A Replace gas hose.

B Gas passage contains

impurities.

B Disconnect gas hose from

the rear of Power Source
then raise gas pressure and
blow out impurities.

C Gas regulator turned off.

C Turn gas regulator on.

D Torch trigger switch lead is

disconnected or
switch/cable is faulty.

D Reconnect lead or repair

faulty switch/cable.

4 No gas flow when the

torch trigger switch is
depressed.

1 The welding arc

cannot be established.

3 Welding current

reduces when
welding.

Table 10-3: Power Source Problems