Section 12: power source error codes, Section 12, Power source error codes -1 – Tweco 300 DC Arcmaster User Manual

Page 63: Arcmaster 300 acdcr

Advertising
background image

ARCMASTER 300 ACDCR

February 22, 2006

12-1

SECTION 12:

POWER SOURCE ERROR CODES

Description

Possible Cause

Remedy

Remarks

A The Welding Power

Source’s duty cycle
has been exceeded.

A Let Power Source

cool down then
keep within its duty
cycle.

B Fan ceases to

operate.

B Have an Accredited

Thermal Arc Service
Agent investigate.

C Air flow is restricted

by vents being
blocked.

C Unblock vents then

let Power Source
cool down.

A The Welding Power

Source’s duty cycle
has been exceeded.

A Let Power Source

cool down then
keep within its duty
cycle.

B Fan ceases to

operate.

B Have an Accredited

Thermal Arc Service
Agent investigate

C Air flow is restricted

by vents being
blocked.

C Unblock vents then

let Power Source
cool down.

A Primary current is

too high because
welding arc is too
long.

A Reduce length of

welding arc.

B Mains supply

voltage is more than
10% below nominal
voltage .

B Have an Accredited

Thermal Arc Service
Agent or a qualified
electrician check for
low Mains voltage.

E04 error code
displayed
Output voltage
exceeds the
secondary voltage
specification.

1 E01 error code

displayed
Temperature sensor
TH1 (protects
IGBTs) is greater
than 80ºC for about
1 second.

Weld current
ceases. Buzzer
sounds constantly.
Fan operates at max
speed.
E01 resets when
TH1 decreases to
70ºC for about 30
seconds.

2 E02 error code

displayed
Temperature sensor
TH2 (protects
secondary diodes)
is greater than 80ºC
for about 1 second.

Weld current
ceases. Buzzer
sounds constantly.
Fan operates at max
speed.
E02 resets when
TH2 decreases to
70ºC for about 30
seconds.

3 E03 error code

displayed
Primary (input)
current too high.

Weld current
ceases. Buzzer
sounds constantly.
Fan operates at max
speed.
Switch machine off
then on to reset E03
error.

4

TIG torch cable
and/or work lead are
too long or leads
are coiled.

Reduce the length
of the TIG torch
cable and/or work
lead or un-coiled
leads.

Weld current
ceases. Buzzer
sounds constantly.
Switch machine off
then on to reset E04
error.

Table 12-1 Power Source Error Codes