Hmc-410 – Tweco HMC-410 User Manual

Page 26

Advertising
background image

HMC-410

2-8

July 27, 2005

NOTE

Refer to the Operation - Softswitch Descrip-
tion chapter of this manual.

13. LOWER DISPLAY — This display shows numerical

information for schedule number, amps, WFS, and
weld sub segment during normal operation. It can also
contain diagnostic test information when diagnostic
are performed.

14. TEST LED — When lit, the control panel is in a test

mode. The test mode allows the weld operator to per-
form the weld schedule with all of its control signals,
timing, and displayed voltages and wire feed speeds.
However the wire feeder and power source will not
operate.

15. TEST BUTTON — This button will toggle the control

panel in and out of test mode. This button has no
effect during a weld.

16. PURGE BUTTON — Depressing the purge button will

allow shielding gas to flow out of the welding gun
without feeding wire. This button has no effect during
a weld.

Art # A-04358

Figure 2-2: Front Panel Controls

10. AMPS LED — When lit, the lower display will show

actual weld current in amps.

NOTE

To have the lower display show amps instead
of wire feed speed, the mode select encoder
will have to be turned.

11. WFS LED — When lit, the lower display shows the

wire feed speed. If the unit is being programmed, this
number represents the programmed wire feed speed.
If the system is welding, the value displayed is actual
wire feed speed.

NOTE

The unit comes from the factory with the WFS
displayed in inches per minute (IPM). The WFS
can be displayed in meters per minute (MPM).
Refer to the Operation - Softswitch Descrip-
tion chapter of this manual.

12. WELD SUB SEGMENT LED — When lit, the lower dis-

play contains the current weld sub segment number.
The weld sub segment number may be from 1 to 4.
The system must be configured for weld sub segment
operation for this to be selectable.