Appendix 7: system outline 2 of 2, Hmc-410, J1 j2 – Tweco HMC-410 User Manual

Page 93: J7 j8, Display/input microprocessor, S2 s3 s4 p.c. board p.c. board, J9 j10

Advertising
background image

HMC-410

July 27, 2005

A-3

DIAGRAM, CONNECTION & SCHEMATIC

HMC-410

NONE

1 OF 4

FULL

ATC

DBB

11-3-99

870241S1

11-3-99

ATC

ATC

11-3-99

130

TECH. PUB.

870241

DIGITAL +5 VDC

2

DIGITAL +5 VDC

3

DISPLAY A SELECT

4

DISPLAY B SELECT

5

DISPLAY C SELECT

6

DISPLAY DATA

7

DISPLAY CLOCK

8

ENCODER 1-A

9

ENCODER 1-B

10

ENCODER 2-A

11

ENCODER 2-B

12

ENCODER 3-A

13

ENCODER 3-B

14

ENCODER 4-A

15

ENCODER 4-B

16

CYCLE START

17

CYCLE STOP

18

TEST

19

INCH

20

PURGE

21

NOT USED

22

NOT USED

23

DIGITAL COM.

24

DIGITAL COM.

25
26

DIGITAL COM.

DIGITAL +5 VDC

1

120 VAC HI (OUT)

J1

26

25

24

23

22

21

20

19

18

17

16

15

14

13

12

11

10

9

8

7

6

5

4

3

2

1

J1

J2

RELAY #1 CONTACT

7

RELAY #2 CONTACT

1

RELAY #2 CONTACT

2
3

ERROR RELAY CONTACT

4

ERROR RELAY CONTACT

5
6

RELAY #1 CONTACT

8

PS CONTACTOR LO

ARC VOLTS (+)

ARC AMPS (+)

REMOTE CONTROL MAX.

REMOTE CONTROL INPUT

ARC ESTABLISHED

ARC AMPS (-)

ARC VOLTS (-)

NOT USED

NOT USED

REMOTE START

REMOTE STOP

GUN SWITCH INPUT

AUX. PURGE

AUX. INCH

AUX. SUBSEGMENT ADV.

AUX. START/STOP

+15 VDC

+15 VDC UNREG.

TACH. SIGNAL

TACH. COM.

GAS VALVE INPUT

24 VAC HI

24 VAC LO

NOT USED

PS CONTACTOR HI

26

25

24

23

22

21

20

19

18

17

16

15

14

13

12

11

10

9

8

7

6

5

4

3

2

1

J6

3

2

1

SUBSEGMENT ENABLE

J4

TRIGGER HOLD ENABLE

DIGITAL COM.

DIGITAL COM.

J5

PROG.\WELD ENABLE

1

2

3

DIG +5VDC

2

DIG +5VDC

3

DIG +15VDC

4

DIG -15VDC

5

NOT USED

6

EXT. AD7

7

EXT. AD6

8

EXT. AD5

9

EXT. AD4

10

EXT. AD3

11

EXT. AD2

12

EXT. AD1

13

EXT. AD0

14

EXT. INT

15

IF0

16

IF1

17

**WR

18

**RD

19

*ALE

20

XTAL1

21

XTAL2

22

*PSEN

23

DIG COM

24

DIG COM

25
26

DIG COM

DIG +5VDC

1

J7

J8

1

18

17

16

15

14

13

12

11

10

9

8

7

6

5

4

3

2

J3

1

A15

NOT USED

26

25

NOT USED

24

ABORT EN.

23

ENGLISH

22

HOLD EN.

21

PROGRAM DELAY EN.

20

SEGMENT SELECT

19

ARC HR RESET

18

TRIM EN.

17

DIAGNOSTICS EN.

16

A0

15

A1

14

A2

13

A3

12

A4

11

A5

10

A6

9

A7

8

A8

7

A9

6

A10

5

A11

4

A12

3

A13

2

A14

S1

12 (K)

120 VAC HI (IN)

PROG./WELD ENABLE

DIGITAL COM.

SUBSEGMENT ENABLE

DIGITAL COM.

TRIGGER HOLD ENABLE

DIGITAL COM.

DISPLAY/INPUT

MICROPROCESSOR

OPTIONAL

S2

S3

S4

P.C. BOARD

P.C. BOARD

LEGEND

S1 ON/OFF SWITCH WITH 4 AMP CIRCUIT BREAKER

S2 TRIGGER HOLD ENABLE SWITCH (OPTIONAL)

S3 SUBSEGMENT ENABLE SWITCH (OPTIONAL)

S4 PROGRAM/WELD SELECT SWITCH

T1 CONTROL TRANSFORMER

11 LINE

OPTIONAL

J9

J10

SEE SHEET 3 FOR OPTIONAL KIT SCHEMATIC

TB-1 TERMINAL BLOCK (OPTIONAL)

J11 SERIAL PORT (OPTIONAL)

SEE SHEET 3 FOR OPTIONAL KIT SCHEMATIC

CHANGE RECORD

E.C. No.

DATE

PLOT DATE

CHECKED

APPROVED

RECORDS

ITEM TYPE

DESIGNED

DRAWN

DATE

SCALE

COMM. CLS.

DESCRIPTIVE DATA

TITLE

MATERIAL SPEC.

MATERIAL NO.

ACTIVITY

FINISH CODE PER

REPLACED BY

REPLACES

QUANTITY-U.M.

DWG. NO.

SIZE

D

FRACT.
INCH

±

SHEET

FILE NAME

DISTRIBUTION TABLE

OUTSIDE DISTR.

6

5

4

3

2

1

4

5

6

1

2

3

H

G

F

E

D

C

B

A

CONFIDENTIAL: This drawing, including all information
contained thereon, is the exclusive and confidential property of
Thermal Arc Corporation of Troy, Ohio 45373 . This drawing is
not to be copied, reproduced, delivered or disclosed to others,
in whole or in part, except with express written permission.

TROY, OHIO 45373 , U.S.A.

ANGLES

± 3˚

UNLESS OTHERWISE SPECIFIED

DIMENSIONS ARE IN INCHES/MILLIMETERS
TOLERANCES BELOW APPLY EXCEPT FOR
VENDOR DESIGNED PARTS AND ITEMS.
PRODUCED TO RECOGNIZED STANDARDS.

DECIMAL-INCH

METRIC

0.00 ± 0.1mm

0.0 ± 0.4mm

0. ± 1.0mm

.000 ± .003

.00 ± .02

DO NOT SCALE DRAWING

.0 ± .1

A THERMADYNE Company

R

R

Art #A-05055

Advertising