Appendix 3: schematic diagram 2 of 4, Hmc-410, J1 j6 – Tweco HMC-410 User Manual

Page 94: J4 j2

Advertising
background image

HMC-410

A-4

July 27, 2005

APPENDIX 3: SCHEMATIC DIAGRAM 2 OF 4

J2

1
2
3
4
5
6
7
8
9

10
11
12
13
14
15
16
17
18

DIGITAL +5 VDC

TACH. SIGNAL

+15 VDC UNREG.

EXT. COM.

EXT. +15 VDC

GROUND FAULT DETECT

WFS CONTROL INPUT

FEEDER RUN ENABLE

WFS TACH. REF.

24 VAC LO

24 VAC HI

NOT USED

FOWARD/REVERSE

DIGITAL +15 VDC

DIGITAL -15 VDC

DIGITAL COM.

DIGITAL COM.

DIGITAL +5 VDC

1

MOTOR (-)

3

4

5

6

7

8

120 VAC HI

2

MOTOR (+)

J1

J6

1
2
3
4
5
6
7
8
9

10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26

PS CONTACTOR HI

NOT USED

24 VAC LO

24 VAC HI

GAS VALVE INPUT

TACH. COM.

TACH. SIGNAL

+15 VDC UNREG.

+15 VDC

AUX. START/STOP

AUX. SUBSEGMENT ADVANCE

AUX. INCH

AUX. PURGE

GUN SWITCH INPUT

REMOTE STOP

REMOTE START

NOT USED

NOT USED

ARC VOLTS (-)

ARC AMPS (-)

ARC ESTABLISHED

REMOTE CONTROL INPUT

REMOTE CONTROL MAX.

ARC AMPS (+)

ARC VOLTS (+)

PS CONTACTOR LO

8

RELAY #1 CONTACT

6

5

ERROR RELAY CONTACT

4

ERROR RELAY CONTACT

3

2

RELAY #2 CONTACT

1

RELAY #2 CONTACT

7

RELAY #1 CONTACT

J8

AUX. INCH
NOT USED
NOT USED
AUX. SUBSEGMENT ADVANCE
AUX. START/STOP
NOT USED
+15 VDC UNREG.
NOT USED
NOT USED
NOT USED
RELAY #2 CONTACT
RELAY #2 CONTACT
ERROR RELAY CONTACT
ERROR RELAY CONTACT
RELAY #1 CONTACT
RELAY #1 CONTACT
NOT USED
NOT USED

AUX. PURGE

V

U

T

S

R

P

N

M

L

K

J

H

G

F

E

D

C

B

A

J7

1

2

3

4

5

6

7

8

J4

J2

A
B
C
D
E
F
G
H
J

K

REMOTE PURGE

NOT USED

NOT USED

NOT USED

NOT USED

NOT USED

+15 VDC UNREG.

REMOTE STOP

REMOTE START

REMOTE INCH

J5

A
B
C
D
E
F
G
H
J

K
L
M
N
P
R
S
T
U
V

MOTOR (+)

24 VAC HI

NOT USED

GAS VALVE INPUT

NOT USED

NOT USED

TACH. SIGNAL

TACH. +15 VDC

TACH. COM.

NOT USED

NOT USED

24 VAC LO

NOT USED

CHASSIS GND

INCH INPUT

NOT USED

GUN SWITCH INPUT

+15 VDC UNREG.

MOTOR (-)

J1

A
B
C
D
E
F
G
H
J

K
L
M
N
P
R
S
T
U
V

PS CONTACTOR HI

ARC VOLTS (-)

ARC AMPS (+)

NOT USED

NOT USED

NOT USED

NOT USED

NOT USED

ARC ESTABLISHED

PS COM.

REMOTE CONTROL MIN.

REMOTE CONTROL INPUT

REMOTE CONTROL MAX.

CHASSIS GND

120 VAC LO

120 VAC HI

ARC AMPS (+)

ARC VOLTS (+)

PS CONTACTOR LO

8 VAC LO

11

17 VAC HI (1)

10

17 VAC LO (1)

9

17 VAC HI (2)

8

17 VAC LO (2)

7

24 VAC HI

6

24 VAC LO

5

4

17 VAC LO (3)

3

2

120 VAC LO

1

8 VAC HI

12

J3

J3

3

120 VAC HI (IN)

2

1

120 VAC HI (OUT)

T1

INTERFACE/SUPPRESSOR

MOTOR CONTROL/

POWER SUPPLY

P.C. BOARD

120 VAC LO

PS. COM.

120 VAC HI

17 VAC HI (3)

POWER

SOURCE

ASSEMBLY

FEEDHEAD

PENDANT

REMOTE

FIXTURE

AUXILIARY

AMPHENOL

AMPHENOL

AMPHENOL

AMPHENOL

P.C. BOARD

TACH. SIGNAL

+15 VDC UNREG.

EXT. +15 VDC

GROUND FAULT DETECT

WFS CONTROL INPUT

FEEDER RUN ENABLE

WFS TACH. REF.

24 VAC LO

EXT. COM.

24 VAC HI

NOT USED

FOWARD/REVERSE

DIGITAL +15 VDC

DIGITAL -15 VDC

DIGITAL COM.

DIGITAL COM.

DIGITAL +5 VDC

DIGITAL +5 VDC

12

11

10

9

8

7

7

8

9

10

11

12

A

B

C

D

E

F

G