N. Auxiliary relays do not function.

1. Interconnecting cable between control panel and

fixture may have a bad connection or short circuit.

a. Repair or replace interconnecting cable.

2. Fixture control relays failure on controller board.

Interconnect between I/S board and controller
board. Interface/Suppressor board failure.

a. Check relay control signal using diagnostic test

#51 and #52. Replace bad component. If these
go bad, also verify that fixture load is not more
than 115 VAC, 2 A, and that proper load
suppression techniques were employed.