4. Equipotential Bonding
Bonding of all metallic components in the welding installation and adjacent to it should be considered. However,

metallic components bonded to the work piece will increase the risk that the operator could receive a shock by

touching the metallic components and the electrode at the same time. The operator should be insulated from all

such bonded metallic components.

5. Earthing/grounding of the Work Piece
Where the work piece is not bonded to earth for electrical safety, nor connected to earth because of its size and

position, e.g. ship’s hull or building steelwork, a connection bonding the work piece to earth may reduce emissions

in some, but not all instances. Care should be taken to prevent the earthing of the work piece increasing the risk

of injury to users, or damage to other electrical equipment. Where necessary, the connection of the work piece to

earth should be made by direct connection to the work piece, but in some countries where direct connection is not

permitted, the bonding should be achieved by suitable capacitance, selected according to national regulations.

6. Screening and Shielding
Selective screening and shielding of other cables and equipment in the surrounding area may alleviate problems

of interference. Screening the entire welding installation may be considered for special applications.

3.06 Power Source Controls, Indicators and Features

Fault

Process

Trigger

Power

2T Normal

STICK

LIFT TIG

MIG

4T Latch

Amps

Volts

Push For Inductance

Advanced

Features

Wirespeed

Arc Control

ON

OFF

Left Knob

Right Knob

Art # A-10123

1

2

3

4

5

6

7

8

9 10

Figure 3-1: Transmig Control Panel