3.15 Installing a Standard Spool (300mm diameter)

As delivered from the factory, the unit is set for a 15 kg or 300mm spool.
Installation of wire spool. Refer to Figure 3-19.

1. Remove Wire Spool Hub Retaining Clip. Grasp the loop and pull.
2. Place Wire Spool onto the hub, loading it so that the wire will feed off the bottom of the spool as the spool

rotates counter clockwise. Make sure to align the spool alignment pin on the hub with the mating hole in the

wire spool.

3. Replace the Wire Spool Hub Retaining Clip in the set of holes closest to the spool.

NOTE

The Wire Wheel Brake has been pre-adjusted at the factory. However if adjustment is required, refer to

Section 3.21

CAUTION

Use care in handling the spooled wire as it will tend to “unravel” when loosened from the spool. Grasp the

end of the wire firmly and don’t let go of it.

A-10340

Wire Spool

Hub Nut

Spring

Flat Washer

Small Hole

Fibre Washer

Spool Hub

300mm

Wire Spool

Retaining Clip

Use outer holes

Keyed Washer

Flat Washer

Large Hole

Pin

Figure 3-19: Standard 300mm Spool Installation