Transmig 250i problems/service – Tweco 250i Multi Process Welding Inverter 2RT Wire Feeder User Manual

Page 82

Advertising
background image

TRANSMIG 250i

PROBLEMS/SERVICE

PROBLEMS AND ROUTINE SERVICE

5-4

Manual 0-5187

C. Earthing/Grounding

The resistance shall not exceed 1Ω between any metal of a power source where such metal is required to be

earthed, and -

1. The earth terminal of a fixed power source; or
2. The earth terminal of the associated plug of a transportable power source

Note that due to the dangers of stray output currents damaging fixed wiring, the integrity of fixed wiring sup-

plying CIGWELD welding power sources should be inspected by a licensed electrical worker in accordance

with the requirements below -

1. For outlets/wiring and associated accessories supplying transportable equipment - at least once every

3 months; and

2. For outlets/wiring and associated accessories supplying fixed equipment - at least once every 12 months.

D. Voltage Reduction Device (VRD)

Units fitted with VRD's, shall have the periodic tests outlined in Table 5-3 below conducted by an accredited

CIGWELD service provider. Testing shall be conducted at intervals as outlined below -

1. For transportable equipment, at least once every 3 months; and
2. For fixed equipment, at least once every 12 months.

Description

Required Parameters

VRD Open Circuit Voltage Less than 35V; at nominal input voltage

VRD Turn ON Resistance

Less than 200 ohms

VRD Turn OFF Time

Less than 0.3 seconds

Table 5-3: VRD Periodic Tests

E. General Maintenance Checks

Welding equipment should be regularly checked by an accredited CIGWELD Service Provider to ensure that:

1. Flexible cord is of the multi-core tough rubber or plastic sheathed type of adequate rating, correctly

connected and in good condition.

2. Welding terminals are in suitable condition and are shrouded to prevent inadvertent contact or short

circuit.

3. The Welding System is clean internally, especially from metal filing, slag, and loose material.

F. Accessories

Accessory equipment, including output leads, electrode holders, torches, wire feeders and the like shall be

inspected at least monthly by a competent person to ensure that the equipment is in a safe and serviceable

condition. All unsafe accessories shall not be used.

G. Repairs

If any parts are damaged for any reason, it is recommended that replacement be performed by an accredited

CIGWELD Service Provider.