3.13 Attaching the Tweco Professional MIG Torch (Euro)

1. Align the pins on the MIG Torch Cable with the pin holes of the MIG Torch receptacle on the front of the system

above the positive(+) dinse type receptacle. Press the MIG Torch in and secure by turning the locking ring to

the right (clockwise)

.

Refer to Figure 3-17.

Attach MIG Torch. Turn

locking ring to the right

Art # A-10338

Figure 3-17: Mount MIG Torch Cable to Adapter Socket

2. If equipped, align the keyways of the MIG Torch Switch connector pigtail with the 8 pin receptacle to the right

of the MIG Torch cable and plug them together. Secure by turning the locking ring to the right (clockwise ).

Refer to Figure 3-17.

NOTE

When disconnecting the MIG Torch trigger switch leads from the machine, DO NOT pull on the wires.

Loosen the locking ring and gently pull the plug out of the socket.