Connect the Inverter

27. Connect the input power connections to the inverters from the contactor. Starting from the top Black, Violet

and red. Repeat if installing a full inverter module.

28. Insert return hose in to the top of the last inverter module installed

• for a 300 and 400 amp system use a 62" long piece of hose
• for a 200 amp system use a 55" long piece of hose

29. Insert 18" piece of interconnection hose between the modules

Art # A-12357