Technical service manual, Pressure adjustment important, Assembly – Viking Pump TSM142.2: LS-M 225/4225 User Manual

Page 14

Advertising
background image

SECTION TSM 142.2
PagE

14 OF 14

ISSUE

E

VIKING PUMP, INC.

A Unit of IDEX Corporation

Cedar Falls, IA 50613 USA

© 3/2013 Viking Pump Inc.

All rights reserved

TECHNICAL SERVICE MANUAL

WARRANTY

Viking warrants all products manufactured by it to be

free from defects in workmanship or material for a

period of one (1) year from date of startup, provided

that in no event shall this warranty extend more than

eighteen (18) months from the date of shipment from

Viking. The warranty period for Universal Seal series

pumps ONLY (Universal Seal models listed below) is

three (3) years from date of startup, provided that in

no event shall this warranty extend more than forty-two

(42) months from the date of shipment from Viking.
UNDER NO CIRCUMSTANCES SHALL VIKING BE

LIABLE UNDER THIS WARRANTY OR OTHERWISE

FOR SPECIAL, INCIDENTAL, INDIRECT,

CONSEQUENTIAL OR PUNITIVE DAMAGES OF ANY

KIND, INCLUDING, BUT NOT LIMITED TO, LOST

OR UNREALIZED SALES, REVENUES, PROFITS,

INCOME, COST SAVINGS OR BUSINESS, LOST OR

UNREALIZED CONTRACTS, LOSS OF GOODWILL,

DAMAGE TO REPUTATION, LOSS OF PROPERTY,

LOSS OF INFORMATION OR DATA, LOSS OF

PRODUCTION, DOWNTIME, OR INCREASED

COSTS, IN CONNECTION WITH ANY PRODUCT,

EVEN IF VIKING HAS BEEN ADVISED OR PLACED

ON NOTICE OF THE POSSIBILITY OF SUCH

DAMAGES AND NOTWITHSTANDING THE FAILURE

OF ANY ESSENTIAL PURPOSE OF ANY PRODUCT.
THIS WARRANTY IS AND SHALL BE VIKING’S SOLE

AND EXCLUSIVE WARRANTY AND SHALL BE IN

LIEU OF ALL OTHER WARRANTIES, EXPRESS

OR IMPLIED, INCLUDING, BUT NOT LIMITED

TO, ALL WARRANTIES OF MERCHANTABILITY,

FITNESS FOR A PARTICULAR PURPOSE AND

NON-INFRINGEMENT ALL OF WHICH OTHER

WARRANTIES ARE EXPRESSLY EXCLUDED.
See complete warranty at www.vikingpump.com.

If the pressure setting of the safety relief valve is to be

changed from that which the factory has set, the following

instructions should be carefully followed: Remove the valve

cap which covers the adjusting screw, and loosen the lock

nut which locks the adjusting screw so pressure setting will

not change during operation of pump. A pressure gauge

somewhere in the discharge line must be used for actual

adjustment operation. The adjusting screw should be turned

in for increasing the pressure or turned out for decreasing the

pressure. With the discharge line closed at a point beyond

the pressure gauge, the gauge will show the maximum

pressure the valve will allow while pump is in operation.

In ordering parts for safety relief valve, always be sure to give

model number and serial number of pump as it appears on

nameplate and the name of the part wanted. When ordering

springs, be sure also to give pressure setting desired.

PRESSURE aDJUSTMENT

IMPORTaNT

DaNgER !

Before starting pump, be sure all drive

equipment guards are in place.
Failure to properly mount guards may

result in serious injury or death.

Reverse the procedure outlined under disassembly.
If valve is removed for repairs, be sure to replace in same

position. The valve cap should point towards the suction

port.

aSSEMBlY

HEaVY-DUTY BRaCKET MOUNTED PUMPS

SERIES 225 aND 4225

SIzES lS, Q, QS, M

Advertising