Danger – Viking Pump TSM143: N-P 335/4335 User Manual

Page 7

Advertising
background image

SECTION TSM

143

ISSUE

E

PAGE 7 OF 15

If the relief valve was not removed from head, install

on head with adjusting screw cap pointed toward the

suction port. Refer to Figure 2, page 2. For

PRESSURE

RElIEf INSTRUCTIONS, refer to page 14.

7. Push the rotor back against the head.
8. Install the drain plug in the casing.

9. Pack the pump with new packing. Refer to Figure 8

.

Models N and R335 have 6 rings of packing. Model

P335 has 8 rings of packing and a lantern ring. The

lantern ring should be installed after the fourth ring of

packing has been assembled into the packing box.

10. Install the thrust bearing housing on the end of rotor

bearing sleeve and tighten the nuts and capscrews

securely. It is not necessary to use a gasket between

these parts.

11. Insert both tapered roller bearings in the thrust bearing

housing, large end of inner races together. It is possible

to install bearings incorrectly, for proper assembly refer

to

Figure

9

.

12. Install the bearing spacer collar on the shaft next to the

inner race of the roller bearing.

13. Turn the inner end cap into the thrust bearing housing

just far enough to hold in place.
Install the outer end cap and turn in approximately half

way.

DANGER !

before starting the pump, be sure all drive

equipment guards are in place.

failure to properly mount the guards may re-

sult in serious injury or death.

fIGURE 9

14. Insert a length of hardwood or brass bar through the port

opening between the rotor teeth to keep the rotor from

turning.

15. Install the lockwasher, placing the tang in the keyway on

the shaft. Tighten the locknut to 170-190 ft – lbs. torque.

Bend one tang of the lockwasher into a slot of locknut.

If tang does not line up with a slot tighten locknut until

it does. Failure to tighten the locknut or engage the

lockwasher tang could result in early bearing failure and

cause damage to rest of the pump.

16. Remove the length of hardwood or brass bar from the

port opening.

17. Install the nuts on the packing gland studs and tighten.

Do not over tighten,as it may cause binding on rotor

shaft.

18. Reinstall the circulation tubing to the casing and rotor

bearing sleeve.

19. Lubricate all grease fittings with multi-purpose grease,

NLGI #2.

20. Adjust the pump end clearance. Refer to

ThRUST

bEARING ADJUSTMENT, page 13.

PUMP

MODEl

A (INCh)

b (INCh)

C (INCh)

N335

4.63

4.69

3.44

R335

5.63

4.69

3.44

P335

6.38

5.75

4.50

fIGURE 8

STUffING bOx DIMENSIONS

C

B

A

Advertising