SECTION TSM 161.3

ISSUE

D

PAGE 7 OF 12

1. Mark head and casing before disassembly to insure

proper reassembly. The idler pin, which is offset in pump

head, must be positioned toward and equal distance

between port connections to allow for proper flow of

liquid through pump.
Remove head from pump.

Do not allow idler to fall from

idler pin. Tilt top of head back when removing to prevent

this. Avoid damaging head gasket. If pump is furnished

with pressure relief valve, it need not be removed from

head or disassembled at this point.

Refer to Pressure

Relief Valve Instructions, page 10.
If LS pump has jacketed head plate, it will separate from

head when it is removed. The gasket between head and

jacket head plate must be totally removed. Use new

gasket when assembling pump. Q, QS and M pumps

have jacketed plate welded to head.

2. Remove idler and bushing assembly.
3. Insert length of hardwood or brass through port opening

between rotor teeth to keep shaft from turning. Bend up

tang of lockwasher and with a spanner wrench remove

locknut and lockwasher from shaft.
Remove length of hardwood or brass from port opening.

4. Standard Mechanical Seal (PTFE fitted type) is setscrew

driven. Setscrews in rotary member must be loosened

before shaft can be removed. Access to collar setscrews

is through seal access hole on left hand side of mounting

bracket (viewed from shaft end,

Refer to figure 5.)

DISASSEMBLY

DANgER !

Before opening any Viking pump liquid

chamber (pumping chamber, reservoir,

relief valve adjusting cap fitting, etc.)

Be sure:
1. That any pressure in the chamber has

been completely vented through the

suction or discharge lines or other

appropriate openings or connections.

2. That the driving means (motor,

turbine, engine, etc.) has been “locked

out” or made non-operational so that

it cannot be started while work is

being done on pump.

3. That you know what liquid the

pump has been handling and the

precautions necessary to safely

handle the liquid. Obtain a material

safety data sheet (MSDS) for the

liquid to be sure these precautions

are understood.

failure to follow above listed

precautionary measures may result in

serious injury or death.

EXPLODED VIEW fOR MODELS Q, QS AND M127

ITEM

NAME Of PART

ITEM

NAME Of PART

ITEM

NAME Of PART

1

Locknut

13

Pipe Plug

25

Idler and Bushing

2

Lockwasher

14

Grease Fitting

26

Idler Bushing

3

End Cap (Outer)

15

Bracket and Bushing

27

Head Gasket

4

Lip Seal for End Cap

16

Capscrew for Bracket

28

Idler Pin

5

Bearing Spacer Collar

17

Bracket Bushing

29

Head and Idler Pin

6

Ball Bearing

18

Bracket Gasket

30

Stud for Head

7

End Cap (Inner)

19

Stud for Flanges

31

Nut for Head

8

Nut for Seal Holder

20

Nut for Flanges

32

Relief Valve Gasket

9

Capscrew for Seal Holder

21

Casing (QS size has opposite ports)

33

Capscrew for Relief Valve

10

Seal Holder Plate

22

Pipe Flange Gasket

34

Internal Relief Valve

11

Seal Holder

23

Pipe Plug

Cover Plate, Relief Valve

12

Mechanical Seal

24

Rotor and Shaft

Advertising