Technical service manual, Pressure adjustment important – Viking Pump TSM163: N-R 337/4337 User Manual

Page 15

Advertising
background image

SECTION TSM 163
PAgE

15 OF 15

ISSUE

D

VIKING PUMP, INC.

A Unit of IDEX Corporation

Cedar Falls, IA 50613 USA

© 3/2013 Viking Pump Inc.

All rights reserved

TECHNICAL SERVICE MANUAL

WARRANTY

Viking warrants all products manufactured by it to be

free from defects in workmanship or material for a

period of one (1) year from date of startup, provided

that in no event shall this warranty extend more than

eighteen (18) months from the date of shipment from

Viking. The warranty period for Universal Seal series

pumps ONLY (Universal Seal models listed below) is

three (3) years from date of startup, provided that in

no event shall this warranty extend more than forty-two

(42) months from the date of shipment from Viking.
UNDER NO CIRCUMSTANCES SHALL VIKING BE

LIABLE UNDER THIS WARRANTY OR OTHERWISE

FOR SPECIAL, INCIDENTAL, INDIRECT,

CONSEQUENTIAL OR PUNITIVE DAMAGES OF ANY

KIND, INCLUDING, BUT NOT LIMITED TO, LOST

OR UNREALIZED SALES, REVENUES, PROFITS,

INCOME, COST SAVINGS OR BUSINESS, LOST OR

UNREALIZED CONTRACTS, LOSS OF GOODWILL,

DAMAGE TO REPUTATION, LOSS OF PROPERTY,

LOSS OF INFORMATION OR DATA, LOSS OF

PRODUCTION, DOWNTIME, OR INCREASED

COSTS, IN CONNECTION WITH ANY PRODUCT,

EVEN IF VIKING HAS BEEN ADVISED OR PLACED

ON NOTICE OF THE POSSIBILITY OF SUCH

DAMAGES AND NOTWITHSTANDING THE FAILURE

OF ANY ESSENTIAL PURPOSE OF ANY PRODUCT.
THIS WARRANTY IS AND SHALL BE VIKING’S SOLE

AND EXCLUSIVE WARRANTY AND SHALL BE IN

LIEU OF ALL OTHER WARRANTIES, EXPRESS

OR IMPLIED, INCLUDING, BUT NOT LIMITED

TO, ALL WARRANTIES OF MERCHANTABILITY,

FITNESS FOR A PARTICULAR PURPOSE AND

NON-INFRINGEMENT ALL OF WHICH OTHER

WARRANTIES ARE EXPRESSLY EXCLUDED.
See complete warranty at www.vikingpump.com.

If a new spring is installed or if the pressure setting of the

pressure relief valve is to be changed from that which the

factory has set, the following instructions must be carefully

followed.
1. Carefully remove the valve cap which covers the

adjusting screw.
Loosen the locknut which locks adjusting screw so the

pressure setting will not change during operation of

pump.

2. Install a pressure gauge in discharge line for actual

adjustment operation.

3. Turn adjusting screw in to increase pressure and out to

decrease pressure.

4. With discharge line closed at a point beyond pressure

gauge, gauge will show maximum pressure valve will

allow while pump is in operation.

In ordering parts for pressure relief valve, always give

model number and serial number of pump as it appears on

nameplate and name of part wanted. When ordering springs,

be sure to give pressure setting desired.

PRESSURE ADjUSTMENT

IMPORTANT

STAINLESS STEEL HEAVY-DUTY PUMPS

SERIES 337 AND 4337

SIZES N AND R

Advertising