Mounting, Piping/hose, General cont’d – Viking Pump TSM341.1: SG Mag Drive Series User Manual

Page 4: Alignment

Advertising
background image

S

D

S

D

S

D

USE STRAIGHT EDGE. THESE SURFACES MUST BE PARALLEL

CHECK WIDTH BETWEEN THESE

SURFACES WITH INSIDE CALIPERS TO BE

CERTAIN THE FACES ARE EQUAL DISTANCE

APART AND PARALLEL

COUPLING

ALIGNMENT

FIGURE 6

SECTION TSM 341.1

ISSUE

J

PAGE 4 OF 19

Mounting

When using an M drive configuration, alignment is insured

by the coupling bracket. If the unit features a bearing carrier,

then a flexible coupling will be required and care should be

given to properly align the bearing carrier to the motor. See

Alignment” on this page.

Since the magnetic coupling is integral to the mounting of

the pump, more specific information is presented under

the

ASSEMBLY and DISASSEMBLY sections presented

elsewhere.
1. Pump mounting surface and canister outer surface must

be clean and free of metal particles.

2. Mounting capscrews must be torqued evenly. See

TABLE 1 below for recommended torque value.

Piping/Hose

The cause of many pumping problems can be traced to

suction piping. It should always be as large in diameter and

as short in length as possible.
Before starting the layout and installation of your piping

system, consider the following points:
1. Never use piping smaller than the pump port connections.

Piping larger in diameter than the port connection is

sometimes is required to reduce suction losses.

2. Be sure the inside of the pipe is clean before installing.
3. When approaching an obstacle in the suction line, go

around instead of over it. Going over obstacle creates an

air pocket. Where practical slope the piping so no air or

liquid pockets will be formed. Air pockets in the suction

line make it hard for the pump to prime.

4. A strainer on the suction side of the pump should always

be considered in any pumping system. The strainer will

keep foreign matter from entering the pump. The strainer

mesh or perforation size should be as fine as possible

to protect the pump without causing excessive pressure

drop. Use of a strainer is particularly important at start up

to help clean the system of weld beads, pipe scale and

other foreign objects.

5. A pressure relief valve is required in the discharge line.

See Pressure Relief Valves,

SPECIAL INFORMATION,

page 3.

6. Pump must not be used to support piping. The weight of

the pipe must be carried by hangers, supports, stands,

etc.

FT-LBs:

Nm:

804

12-15

16-20

805

12-15

16-20

807

31-34

42-46

810

50-65

68-88

814

50-65

68-88

TABLE 1

FIGURE 3

Clockwise Rotation

of 804 & 805

(Viewed From Shaft End)

FIGURE 4

Clockwise Rotation

of 807

(Viewed From Shaft End)

FIGURE 5

Clockwise Rotation

of 810 & 814

(Viewed From Shaft End)

General Cont’d

3. Suction/Discharge - SG/SGN Series pumps are designed

for clockwise rotation as standard (viewed from end

of shaft). Refer to

Figure 3, Figure 4 and Figure 5.

Always check rotation arrow on nameplate before

mounting and start-up.

3. Do not strike or press the inner magnet coupling half

to install on the pump shaft. Damage to the pump or

coupling may result if the coupling does not slide onto

pump shaft, inspect the coupling bore, shaft and key for

nicks or burrs and remove if present.

4. Once the pump has been mounted, place a small

amount of compatible liquid into the suction port and turn

by hand to ensure the pump turns freely.

Alignment

Check alignment after mounting on units with a bearing

carrier.
1. If the unit has a flexible coupling, remove any coupling

guards or covers and check alignment of the coupling

halves. A straight edge (piece of key stock will work)

across the coupling must rest evenly on both rims at the

top, bottom and sides. See

Figure 6.

2. Make final check of alignment after the piping is hooked

up. Replace the guards.