TSM 343.1 ISSUE D PAGE 2 OF 13

SPECIAL INfORMATION

Rotation:

Although shaft rotation determines which port is suction and

which is discharge, Viking magnetic drive composite pumps

are designed to run in a designated direction (indicated on

pump decal).

Pressure Relief Valves:

1. Relief valves are mounted on the head or casing of all

RP series composite pumps.

2. The RP series is a positive displacement pump and

requires some sort of over pressure protection. Without

over pressure protection, the following is likely to occur:

motor stalls, drive equipment fails, a pump part breaks

and the piping and/or equipment in the system bursts.

This may be an internal relief valve.

3. If a relief valve is not furnished on the pump, some means

of over pressure protection such as an in-line relief valve

should be provided.

4. If pump rotation is to be reversed during normal

operation, pressure protection must be provided on both

sides of pump.

5. Relief valve adjusting screw cap must always point

towards suction side of pump.

6. Pressure relief valves cannot be used to control flow to

regulate pressure.

For additional information on pressure relief valves, refer to

Technical Service Manual TSM 000 and Engineering Service

Bulletin ESB-31.

INSTALLATION

General

The following items must be considered prior to pump

installation:
1. Location - locate the pump as close as possible to supply

of liquid being pumped. If possible locate pump below

liquid supply. Viking pumps are self-priming; but, the

better the suction conditions the better the pump will

perform.

2. Accessibility - pump must be accessible for inspection,

maintenance and repair.

3. Suction/Discharge - SG Series pumps are designed for

clockwise rotation as standard (viewed from end of shaft).

Refer to Figure 3.

Mounting

1. The pump mounting surface must be clean and flat.
2. Use SAE Grade 5 or better capscrews to mount pump.
3. The mounting capscrews for RP-05 & RP-07 pumps must

have a minimum of ½ inch thread engagement.

4. Mechanical Seal and Lip Seals RP Series pumps are

designed to be used with jaw type couplings that do not

induce axial thrust on the pump shaft. If an improper type

coupling is used, internal damage may result.

5. Do not strike or press inner magnet coupling half to install

on the pump shaft. Damage to pump or coupling may

result if coupling does not slide onto pump shaft, inspect

coupling bore, shaft and key for nicks or burrs and

remove if present.

6. Once pump has been mounted, place a small amount of

compatible liquid into suction port and turn by hand to

ensure pump turns freely.

Alignment

Check alignment after mounting of units with a bearing

carrier.
1. If unit has flexible coupling, remove any coupling guards

or covers and check alignment of coupling halves. A

straight edge (piece of key stalk will work) across coupling

must rest evenly on both rims at top, bottom and sides.

See Figure 4.

2. Make final check on alignment after piping is hooked up.

Replace the guards.

DANGER

BEFORE OPENING ANY VIKING PUMP LIQUID

CHAMBER (PUMPING CHAMBER, RESERVOIR,

RELIEF VALVE ADJUSTING CAP FITTING ETC.)

BE SURE:
1. THAT ANY PRESSURE IN CHAMBER HAS

BEEN COMPLETELY VENTED THROUGH

SUCTION OR DISCHARGE LINES OR OTHER

APPROPRIATE OPENINGS OR

CONNECTIONS.

2. THAT THE DRIVING MEANS (MOTOR,

TURBINE, ENGINE, ETC.) HAS BEEN “LOCKED

OUT” OR MADE NON- OPERATIONAL SO THAT

IT CANNOT BE STARTED WHILE WORK IS

BEING DONE ON PUMP.

3. THAT YOU KNOW WHAT LIQUID THE PUMP

HAS BEEN HANDLING AND THE

PRECAUTIONS NECESSARY TO SAFELY

HANDLE THE LIQUID. OBTAIN A MATERIAL

SAFETY DATA SHEET (MSDS) FOR THE

LIQUID TO BE SURE THESE PRECAUTIONS

ARE UNDERSTOOD.

FAILURE TO FOLLOW ABOVE LISTED

PRECAUTIONARY MEASURES MAY RESULT IN

SERIOUS INJURY OR DEATH.

DANGER

RUNNING THE PUMP IN THE OPPOSITE

DIRECTION TO THE DESIGNATED DIRECTION

MAY RESULT IN SERIOUS INJURY OR DEATH.

PAGE 2 Of 13