Technical service manual – Viking Pump TSM410.1: F-FH 4625 User Manual

Page 5

Advertising
background image

SECTION TSM 410.1
PaGE

5 OF 5

ISSUE

D

VIKING PUMP, INC.

A Unit of IDEX Corporation

Cedar Falls, IA 50613 USA

© 3/2013 Viking Pump Inc.

All rights reserved

TECHNICAL SERVICE MANUAL

WARRANTY

Viking warrants all products manufactured by it to be

free from defects in workmanship or material for a

period of one (1) year from date of startup, provided

that in no event shall this warranty extend more than

eighteen (18) months from the date of shipment from

Viking. The warranty period for Universal Seal series

pumps ONLY (Universal Seal models listed below) is

three (3) years from date of startup, provided that in

no event shall this warranty extend more than forty-two

(42) months from the date of shipment from Viking.
UNDER NO CIRCUMSTANCES SHALL VIKING BE

LIABLE UNDER THIS WARRANTY OR OTHERWISE

FOR SPECIAL, INCIDENTAL, INDIRECT,

CONSEQUENTIAL OR PUNITIVE DAMAGES OF ANY

KIND, INCLUDING, BUT NOT LIMITED TO, LOST

OR UNREALIZED SALES, REVENUES, PROFITS,

INCOME, COST SAVINGS OR BUSINESS, LOST OR

UNREALIZED CONTRACTS, LOSS OF GOODWILL,

DAMAGE TO REPUTATION, LOSS OF PROPERTY,

LOSS OF INFORMATION OR DATA, LOSS OF

PRODUCTION, DOWNTIME, OR INCREASED

COSTS, IN CONNECTION WITH ANY PRODUCT,

EVEN IF VIKING HAS BEEN ADVISED OR PLACED

ON NOTICE OF THE POSSIBILITY OF SUCH

DAMAGES AND NOTWITHSTANDING THE FAILURE

OF ANY ESSENTIAL PURPOSE OF ANY PRODUCT.
THIS WARRANTY IS AND SHALL BE VIKING’S SOLE

AND EXCLUSIVE WARRANTY AND SHALL BE IN

LIEU OF ALL OTHER WARRANTIES, EXPRESS

OR IMPLIED, INCLUDING, BUT NOT LIMITED

TO, ALL WARRANTIES OF MERCHANTABILITY,

FITNESS FOR A PARTICULAR PURPOSE AND

NON-INFRINGEMENT ALL OF WHICH OTHER

WARRANTIES ARE EXPRESSLY EXCLUDED.
See complete warranty at www.vikingpump.com.

the bore and lapped face of the rotary member of

the mechanical seal with light oil and slide onto the

rotor shaft Position the drive pins in two holes in

back of the rotor Slide the rotor into the pump casing

4. Place nine 0 002 inch ( 018 inch total) gaskets on

the head Place the idler on the head and install into

the pump casing Install three capscrews (every

other one), tighten finger tight then loosen one turn

5. Slide bearing retainer washer onto the drive end of

the rotor shaft and position against the shoulder on

the shaft Slide the ball bearing onto the shaft and

into the bore of the casing as far as it will go easily

At this point slide a sleeve over the drive end of the

shaft and up against the inner race of the bearing

and press the bearing into place

6. Install

the lockwasher & locknut Tighten the locknut

to 15-20 ft – lbs Torque (F-FH) Tighten the nut

securely and bend the tang of the lockwasher into

the slot of the locknut

NOTE: Hold the rotor shaft from turning while

tightening the locknut by fastening a wrench on the

flat of the shaft

7. Install

the packing nut and tighten securely

8. Tighten the three capscrews Add or remove

gaskets (using either 001 or 003) until the rotor

drags slightly on the head; then add two 001 thick

gaskets End clearance is now set properly Put in

the remaining three capscrews and double check to

be sure the rotor is free to turn

NOTE: If the capacity of the pump has decreased after long

term operation, it is sometimes possible to increase the

capacity again by removing (1) or more head gaskets If this

is done be sure to turn pump over by hand before starting
DO NOT OPERaTE PUMP “DRY”; make sure there is

a supply of liquid in the suction line prior to start-up

abRaSIVE lIqUID PUMPS

SERIES 4625

SIZES F - FH

.0625

HEaD

FaCE

Advertising