Danger – Viking Pump TSM630: H-LL Universal Seal User Manual

Page 4

Advertising
background image

SECTION TSM 630

ISSUE

H

PAGE 4 OF 12

FIGURE 4 - EXPLODED VIEW SERIES 4123A, 4124A, 4124AE, 4126A, AND 4127A MODELS

ITEM

NAME OF PART

ITEM

NAME OF PART

ITEM

NAME OF PART

1

Locknut

10

Cartridge Seal

19

Idler and Bushing Assembly

2

Lockwasher

11

Capscrew for Bracket

20

Idler Bushing

3

End Cap

12

Grease Fitting

21

Head Gasket

4

Lip Seal

13

Bracket and Bushing Assembly

22

Idler Pin

5

Bearing Spacer Collar (Outer)

14

Bracket Bushing

23

Head and Idler Pin Assembly

6

Ball Bearing

15

Bracket Gasket

24

Capscrew for Head

7

Bearing Spacer Collar (Inner)

16

Pipe Plug

25

Relief Valve Gasket

8

Ring, Half Round (Not H, HL)

17

Casing (Tapped or Flanged)

26

Internal Relief Valve

9

Bearing Housing

18

Rotor and Shaft Assembly

27

Capscrew for Valve

REPAIR: MODELS H, HL, K, KK, L, LQ AND LL

CARTRIDGE MECHANICAL SEAL PUMPS

DANGER !

Before opening any Viking pump liquid

chamber (pumping chamber, reservoir,

relief valve adjusting cap fitting, etc.)

Be sure:
1. That any pressure in the chamber has

been completely vented through the

suction or discharge lines or other

appropriate openings or connections.

2. That the driving means (motor,

turbine, engine, etc.) has been “locked

out” or made non-operational so that

it cannot be started while work is

being done on pump.

3. That you know what liquid the

pump has been handling and the

precautions necessary to safely

handle the liquid. Obtain a material

safety data sheet (MSDS) for the

liquid to be sure these precautions

are understood.

Failure to follow above listed

precautionary measures may result in

serious injury or death.

CARTRIDGE MECHANICAL

SEAL REPLACEMENT

CARTRIDGE MECHANICAL

SEAL REMOVAL

MODELS:
H, HL, K, KK, L ,LQ, LL4124A AND LL4124AE CAST IRON

H, HL, K, KK, L, LQ, AND LL4126A DUCTILE IRON

H, HL, K, KK, LQ, AND LL4123A STEEL

H, HL, K, KK, LQ, AND LL4127A STAINLESS STEEL
For complete pump
disassembly and assembly see

pages 7 and 8.

1. Bend up tang of lockwasher and with a spanner wrench,

remove locknut and lockwasher from shaft.

2. Loosen two set screws in the face of the bearing housing

and remove the bearing housing assembly from the

bracket.

3. Remove the pair of half round rings under the inner

spacer collar from the shaft. There are no half round

rings on the “H” and “HL” size pumps.

4. If flush or barrier fluid tubes are connected to the seal

gland, disconnect before removing seal. Loosen the set

screws on the cartridge seal collar to free the cartridge

seal from the shaft. Remove the two gland capscrews

and slide cartridge seal out through bearing housing

opening.