SECTION TSM 845

ISSUE

F

PAGE 11 OF 14

ADJUSTING HEAD GASKET

END CLEARANCE

PUMP ROTATION

Use either of the following procedures to properly adjust the

end clearance when replacing gaskets:

PROCEDURE A:
With balance plate in position, slide rotor and shaft into

casing Insert a feeler gage of the proper thickness into the

port and between two rotor teeth

(See Figure 20 on page

10). Install one 0 015” and one 0 007” gasket onto head

With the idler on the idler pin, place the head into the pump

casing With the capscrews tight, the feeler gage should fit

snugly, otherwise gaskets should be added or removed until

the proper clearance is attained

The pump is designed to take fluid from the discharge side

of the pump and channel it down the idler pin into the shaft

and out into the canister through the capscrew which secures

the inner magnet The fluid is returned through a hole in

the casing back to the suction side of the pump There are

generally three parts which may need replacing or adjusting

to change rotation
HEAD & PIN – Hole should be from the discharge side of

head to the pin and a pipe plug is placed in the tapped hole

on the suction side of the head To change rotation, move the

plug to the opposite side of the head
BALANCE PLATE – If the plate is separate from the bracket

and looks like the Style A in

Figure 22, it can be reversed The

groove should connect the discharge port to the bushing bore

If rotation is changed, the plate is flipped over (not rotated)

and the groove would not be visible but will still function

properly If the plate is like Style B, it is

NOT reversible and a

new plate will be required
BRACKET – The bracket will have two holes drilled through

and tapped on one side The discharge side of the bracket

should feature a pipe plug with a hole drilled through it To

change rotation simply move this pipe plug to the other hole
Contact your local Viking distributor or the factory to determine

which parts are required

PROCEDURE B:
If the pump is in line and the ports are not accessible,

remove the head and gaskets Put the head back on (without

gaskets) and measure the gap as shown

(See Figure 21 on

page 10). After determining the gap between the head and

casing, select a combination of gaskets with approximately

25% more total thickness than the gap plus the required end

clearance Note that the gaskets will compress when head is

tightened down Remove the head, install all gaskets then

replace the head Tighten the head capscrews and check

the pump clearance by making sure the pump turns freely

by hand
Since the pump shaft is concealed, it is best to work up the

proper end clearance because it is difficult to determine when

there is to much end clearance with this approach

FIGURE 20

FIGURE 21

FIGURE 22

STYLE B

STYLE A

GROOVE

Advertising