DO NOT OPERATE PUMP IF:
– The front cover is not installed correctly
– Any guards are missing or incorrectly installed
– The suction or discharge piping is not connected
DO NOT place fingers, etc into the pumping chamber

or its connection ports or into any part of the drive train

if there is ANY possibility of the pump shafts being

rotated Severe injury will occur
DO NOT exceed the pumps rated pressure, speed, and

temperature, or change the system/duty parameters

from those for which the pump was originally supplied,

without confirming its suitability for the new duty
INSTALLATION AND OPERATION OF THE PUMP

MUST ALWAYS COMPLY WITH HEALTH AND

SAFETY REGULATIONS.
Rare earth magnets used in couplings have

extremely strong magnetic fields capable of

changing performance or damaging items such as:

Pacemakers, Metal Implants, Watches, Computers

& Disks, and Credit Cards
Completely assembled magnetic couplings will

not affect items listed above - only disassembled

components
There are no known harmful effects of these

magnetic fields on the human body
A device must be incorporated into the pump, system,

or drive to prevent the pump exceeding its stated duty

pressure It must be suitable for both directions of

pump rotation where applicable Do not allow pump

to operate with a closed/blocked discharge unless a

pressure relief device is incorporated If an integral

relief valve is incorporated into the pump, do not allow

re-circulation through the relief valve for extended

periods
The mounting of the pump or pump unit should be

solid and stable Pump orientation must be considered

in relation to drainage requirements Once mounted,

shaft drive elements must be checked for correct

alignment Rotate pump shaft by at least one full

revolution to ensure smoothness of operation

Incorrect alignment will produce excessive loadings

and will create high temperatures and increased noise

emissions Do not use any drive arrangements which

cause sideloading of the drive shaft
The installation must allow safe routine maintenance

and inspection (to check for leakage, monitor

pressures, etc) and provide adequate ventilation

necessary to prevent overheating

Before operating the pump, be sure that it and all

parts of the system to which it is connected are clean

and free from debris and that all valves in the suction

and discharge pipelines are fully opened Ensure that

all piping connecting to the pump is fully supported

and correctly aligned with its relevant connections

Misalignment and/or excess loads will cause severe

pump damage
Be sure that pump rotation is correct for the desired

direction of flow
DO NOT INSTALL THE PUMP INTO A SYSTEM

WHERE IT WILL RUN DRY (I.E. WITHOUT A

SUPPLY OF PUMPED MEDIA).
Pressure gauges/sensors are recommended, next

to the pump suction and discharge connections to

monitor pressures
Caution must be taken when lifting the pump Suitable

lifting devices should be used as appropriate Lifting

eyes installed on the pump must only be used to lift

the pump, not pump with drive and/or baseplate If

pump is baseplate mounted, the base plate must be

used for all lifting purposes If slings are used for lifting,

they must be safely and securely attached For weights

of bare shaft pumps refer to catalog
DO NOT attempt any maintenance or disassembly of

the pump or pump unit without first ensuring that :
– The pump is fully isolated from the power source

(electric, hydraulic, pneumatic)

– The pumping chamber, relief valve and any

shaft seal support system are depressurized and

purged

– Any temperature control devices (jackets, heat-

tracing, etc) are fully isolated, that they are

depressurized and purged, and components are

allowed to reach a safe handling temperature

DO NOT attempt to dismantle a pressure relief valve

which has not had the spring pressure relieved or is

mounted on a pump that is operating Serious personal

injury or death and/or pump damage may occur
DO NOT loosen or undo the front cover, any

connections to the pump, shaft seal housings,

temperature control devices, or other components,

until sure that such action will not allow the unsafe

escape of any pressurized media
Pumps and/or drives can produce sound power levels

exceeding 85 dB(A) under certain operating conditions

When necessary, personal protection against noise

must be taken
Avoid any contact with hot parts of pumps and/or

drives which may cause injury Certain operating

conditions, temperature control devices (jackets, heat-

tracing, etc ), bad installation, or poor maintenance

can all promote high temperatures on pumps and/or

drives

WARNING

SAFETY INFORMATION

Danger - Failure to follow the listed

precautionary measures identified by

this symbol may result in serious injury

or death

Warning - Safety instructions which

shall be considered for reasons of safe

operation of the pump or pump unit and/

or protection of the pump or pump unit

itself are marked by this symbol

INCORRECT INSTALLATION, OPERATION OR MAINTENANCE OF EQUIPMENT MAY CAUSE SEVERE
PERSONAL INJURY OR DEATH AND/OR EQUIPMENT DAMAGE AND MAY INVALIDATE THE WARRANTY.