Veris Drive Calibrating Instructions
Refer to Figure 16
17. Enter the actual amount metered using the Up/
Down arrow keys. Press Function key to ad-
vance to next window.
Refer to Figure 17
18. A New calibration number is suggested, along
with the Old calibration number.
Refer to Figure 18
19. Press Function key to advance to window
shown.
20. If you wish to keep the Old number, perhaps to
rerun the calibration procedure, press the Down
arrow key. If you want to accept the New calibra-
tion number, press the Up arrow key.