Veris Drive Calibrating Instructions

Refer to Figure 16

17. Enter the actual amount metered using the Up/

Down arrow keys. Press Function key to ad-
vance to next window.

Refer to Figure 17

18. A New calibration number is suggested, along

with the Old calibration number.

Refer to Figure 18

19. Press Function key to advance to window

shown.

20. If you wish to keep the Old number, perhaps to

rerun the calibration procedure, press the Down
arrow key. If you want to accept the New calibra-
tion number, press the Up arrow key.

22785

22786

22731

Figure 16

Figure 17

Figure 18