Great Plains YP1625 Material Rate User Manual
Page 40
Advertising

401-226B
8/8/2006
40
Refer to Figure 19
21. Console window now displays the calibration
number you have selected.
Refer to Figure 20
22. This returns you back to the beginning of Cali-
bration mode as shown. To rerun the Calibration
procedure, follow the steps outlined in step 20. It
is suggested that you perform the calibration
mode at least twice, and additional replications
may be needed if Target and Actual amounts
vary significantly.
Speed Calibration
In order to fine-tune the default speed calculation or
to convert to radar speed signal, the controller may
be calibrated as follows:
Refer to Figure 21
1.
To calibrate the Controller for speed, press the
Function key until the screen appears, as
shown.
22787
22733
22788
Figure 19
Figure 20
Figure 21