OPERATOR’S MANUAL

PM300, PM332, PM400 Planter Monitors

11001-1372-200606

INTRODUCTION / 5

SPECIFICATIONS

Power

10–16 VDC, 5 A maximum

Operating temperature range

-20°C to 70°C (-4°F to 158°F)

Storage temperature range

-40°C to 85°C (-40°F to 185°F)

Size

18.4 cm W x 20.1 cm H x 4.3 cm D
(7.3" W x 7.9" H x 1.7" D)

Weight

4.4 lbs for 16-row PM300 system
4.8 lbs for 32-row PM332 system
6.4 lbs for 36-row PM400 system
*Weight includes console and attached
cables (battery power cable and signal
cable that extends to the drawbar).

Wire Harnesses

The PM300, PM332, and PM400 include
integrated harnesses to supply the unit's
power (fused), ground speed input, and
sensor inputs (to drawbar). The connectors
are compatible with existing DICKEY-john
harnesses. DICKEY-john can supply
custom harnesses required for sensor
inputs.

Sensors

Compatible with existing DICKEY-john
sensors

Standard mounting

Rear attached horizontal or vertical
mounting bracket
Mounting bracket weighs 1.0 lb.

Optional mounting

Three-axis adjustable mounting bracket

Contrast adjustment

Automatic temperature compensation for
contrast

Backlight adjustment

Three settings for full sun, daytime, or
nighttime use

CE certified

Dust and moisture resistant

Advertising