To perform a new calibration:

1. Measure a 400 foot (122 meter) course, clearly marking the beginning

and end.

2. Using the Arrow keys, highlight the Start softkey on the screen ( X ).
3. Begin moving the tractor forward at 2-5 mph.
4. When the tractor is even with the beginning marker, press the Enter

key to start the 400-foot calibration.

5. After the calibration has begun, the softkey on the screen will change

to a Stop ( „ ) softkey. Drive 400 feet and stop the vehicle.

6. Select the Enter key to stop the calibration. The new calibration factor

will be displayed on the window.

7. Once the Stop key is selected, the value will be saved upon screen

exit. Selecting the Escape key while the calibration is running will not
save the value.

8. Select either the Escape or Operate key to return to the Operate

(main) screen.