KEY FUNCTIONS

Figure 8
Keys

ON/OFF KEY

The On/Off key activates the unit. During power up, the monitor performs
internal self-tests, illuminates the display, sounds the alarm, and determines
which sensors are connected to the system. Pressing and holding the key
for one second when the power is ON will turn the power OFF, independent
of the screen being displayed.

ALARM CANCEL KEY

During normal operation, selecting the Alarm Cancel key acknowledges
the alarm condition displayed on the screen. Active row alarms are reset
after an ALL ROWS FAILURE condition or a power down-up sequence
occurs. If the error condition continues, the key must be selected again to
cancel the alarm. When no alarms are active, the volume may be modified
by selecting and holding the Alarm Cancel key.