OPERATOR’S MANUAL

PM300, PM332, PM400 Planter Monitors

11001-1372-200606

ADVANCED SETUP / 31

Figure 19
Service Screen

SECURITY SCREEN

Security features allow password protection security levels to be activated
(refer to Figure 20). This prevents unauthorized personnel from modifying
key parameters in the field.

The password screen allows the operator to individually lock screens to
assure they are not modified.

To Lock and Unlock Screens:

1. Press the Display & Service key.
2. Using the Arrow keys, highlight the Security icon and press the Enter

key to enter a password.

3. Modify the digits and select the Enter key again to accept the

password.

4. Highlight the Configuration key and press Enter to navigate to the list

of screens.

5. Use the Up or Down Arrow key to highlight icon for editing.
6. Press Enter to select the Lock/Unlock icon.
7. Lock or unlock screens by pressing the Up or Down Arrow keys.
8. Press Enter key to accept Lock or Unlock.
9. Select the Escape key to return to the Password screen.

10. Highlight the padlock and select the Enter key to toggle the unlocked

state to locked. The selected screens will require input of the password
prior to modification.

M : 0 3 0 5 0 2 2 1 0 9

B : 0 2 0 5 0 3 0 7 1 4

H : 1

25.7

910.0

ac

12.8

1

2

Total hours of
operation

Total acres
covered

Hardware and
software versions

Battery voltage

Hopper Level 1 and 2

sensor status

Lift switch

status

ESCAPE

ENTER

Security icon

Up or Down Arrow keys

Enter key

Escape key