5317-5323 hydraulic down pressure – Great Plains TC5319 (S/N A1420X+) Operator Manual User Manual

Page 21

Advertising
background image

Great Plains Manufacturing, Inc.

Preparation and Setup

17

03/06/2014

566-224M

5317-5323 Hydraulic Down Pressure

Refer to Figure 13
Note: This setup procedure is for tractors with closed-center

or pressure compensated flow hydraulic systems.
Open center hydraulics not supported.Adjust down
pressure valve as shown on decal

(located on front

right hand truss), Refer to Figure 14.

Never leave tractor valve centered when unfolded with machine
in motion. Machine damage may occur when wings flex up or
down

This machine is designed for continuos hydraulic flow to the wing
fold cylinders during field operations. It is for use on tractors
having CLOSED CENTER hydraulics only. If your tractor has an
OPEN CENTER hydraulics, please consult your dealer for oper-
ating instructions.

25. Adjust the bypass/pressure reducing valve by turning

knob

clockwise all the way in and then backing out 1

full turn.

26. On tractor, adjust flow-control valve to low side of flow

rate.

Note: The faster the flow of oil through the system the

greater the potential for oil heating, premature wear
or tractor damage.

27. Lock the fold hydraulic lever for continuous downward

oil flow.

28. Adjust bypass/pressure reducing valve knob

on

implement so the pressure gauge

reads 1200 psi.

Never exceed 1400 psi.

29. While watching pressure gauge

, slowly open knob

until gauge reads 1100psi. Pressure might rise and
then fall off as knob is opened. If pressure exceeds
1400 psi during this step, the tractor flow is too high,
reduce tractor flow. Lock valve knob

at 1100 psi.

30. Finally adjust valve

to the desired wing down pres-

sure setting. Never exceed 900 psi.

31. In field operation, lock the fold hydraulic lever for con-

tinuous downward oil flow. If wings are running too
high, increase pressure setting, knob

, to level

machine. If center is too high, decrease pressure set-
ting with knob

on valve.

.

Figure 13

5317-5323 Down Pressure

41296

2

1

4

3

U

D

F

B

L

R

4

Figure 14

Down Pressure Decal

848-390C

1

2

3

3

1

1

2

2

2

Advertising