25 series coulter row alignment – Great Plains 2525F Operator Manual User Manual

Page 39

Advertising
background image

Adjustments 35

01/23/2012

118-232M

25 Series Coulter Row Alignment

Refer to Figure 43
For 25 Series unit-mounted coulters, the ideal alignment
is for the blade to open a furrow directly ahead of the
opener discs.

As a check on coarse alignment, sight along the coulter
blade centerline

, the gap between the opener blades

, and the centerline between the press wheels

. If

they are clearly out of alignment, either the coulter or the
press wheels (or both) may be in need of adjustment.

The exacting test of correct alignment is field results.
Operate the drill on some test ground (no seed required),
and verify that the opener blades are in the groove
opened by the coulter, and that the press wheels are
centered over the furrow. See “Press Wheel Adjust-
ment
” on page 40 f
or press wheel alignment.

FigureSpacer

Refer to Figure 43
To adjust coulter alignment, loosen the four bolts

that

attach its bracket to the row unit. The holes on the row
unit are slotted, side-to-side, and allow the coulter
bracket sideways and rotational adjustment.

Keep the coulter blade vertical while adjusting.

If the blade cannot be brought into alignment, check that
the blade spindle itself is using the same hole location on
each side of the bracket.

FigureSpacer

Figure 43

25 Series Coulter Alignment

26125

1

2

3

1

2

3

FigureSpacer

Figure 44

25 Series Coulter Mount

29135

4

4

Advertising