Great Plains Mfg., Inc.

Installation Instructions

19

02/29/2008

407-197M

Install H.R. Orifices

Refer to Figure 36
The nozzles do not have orifice plates

pre-installed, as

there is a choice of 3 sizes included. Consult the planter
Operator and Seed Rate manuals and determine which
plate size is the most likely for your next application.

102. Select one of the following sets:

103. Twist to unlock each nozzle, insert a plate,. and re-

lock.

Note: You can skip any positions that are to be capped at

Step 108.

Note: No special precautions are necessary at this time,

but after using the system, always wear protective
gloves when changing orifice plates.

Install H.R. Drop Lines

If your planter has fewer than 32 high rate zones, some
positions get caps instead of drop lines.

104. Raise the planter and install transport locks.

105. Lower the row units.

106. Select:

107. If not already installed on the nozzles, select:

Not all of the caps may be used.

Qty

Call

Part

Description

32

832-053C ORIFICE SPR SYS CP4916-34 SS

32

832-054C ORIFICE SPR SYS CP4916-48 SS

32

832-056C ORIFICE SPR SYS CP4916-28 SS

Figure 36

H.R. Orifice Installation

21983

4

4

346

347

348

Qty

Call

Part

Description

-

990-080R HOSE 3/8 ID 150PSI EPDM

64

800-126C CLAMP WRM DRV #5 SS (.44-.70)

16

832-042C NOZZLE SHUT OFF CAP W/ GASKET

32

800-303C CABLE TIE 2 DIA MIN - BLK

Qty

Call

Part

Description

32

830-071C AD 1/4MNPT X 3/8HB POLYPROP

350

319

344

321

334

Advertising