Mount starter booms, Install starter relief valve – Great Plains YP Fertilizer System User Manual

Page 22

Advertising
background image

Great Plains Mfg., Inc.

22

Fertilizer System

407-197M

02/29/2008

Mount Starter Booms

The starter boom mounts to components installed for the
high rate boom.

Refer to Figure 40
120. Select:

121. Loosely mount each boom in the wing’s the boom

mounting brackets

(or the upper position of

+

) using the U-bolts and lock nuts.

122. Adjust the boom to roughly align its ends with the

ends of the tube of the air system support frame.
Tighten the lock nuts.

Install Starter Relief Valve

Refer to Figure 41
123. Select the relief valve assembly

, which does not

have a specific part number.

124. Select (or remove from assembly above):

125. Install the relief valve:

• near the ground drive pump (on the left wing),

• on the air system support frame tube,

• with the valve toward planter center, and

• the gauge face facing planter center (facing for-

ward during field operations).

Qty

Call

Part

Description

12

806-152C U-BOLT 1/4-20 X 1.125 X 2 RND

24

803-088C NUT HEX LOCK 1/4-20 FLG

Figure 40

Starter Boom Tee

27100

166

168

311

310

168

166

311

311

310

Qty

Call

Part

Description

1

401-528D AIR TUBE SUPPORT CLAMP

2

890-521C MUFFLER CLAMP 1.63 SIZE

Figure 41

Starter Relief Valve Assembly

27094

1

153

192

192

1

153

192