Starter Hose to Right Wing Boom

134. Fold the planter to ensure that an adequate length of

hose is installed between the wings.

135. Select:

Refer to Figure 44 and Figure 45
136. Route the hose

:

• from the starter relief valve

• to the left wing hydraulic hose bundle or the high

rate hose (under the seed meter conduit, above
the row unit tool bar)

• along the hydraulic/high rate hose bundle to the

right wing

• to the elbow/tee at the center of the right boom.

137. Connect the hose to the adaptor

at the outlet tee

of the relief valve assembly. Secure with clamp

.

138. Allowing some slack, use cable ties every 16in or so

to secure the hose to the hydraulic/high rate bundle.

Refer to Figure 46 (which depicts older mount brackets)
139. At the right wing cut the hose to length at the elbow/

tee at the center of the boom and secure with clamp

.

Qty

Call

Part

Description

-

990-081R HOSE 3/4 ID 200PSI EPDM

2

800-257C CLAMP WRM DRV #20SS (.81-1.75)

Figure 44

Starter Relief Valve to Right Boom

27113

163

5

194

194

163

Figure 45

Wing-to-Wing Hose at Center

27101

194

5

163

Figure 46

Wing-to-Wing Hose at Right Wing

27102

163

163