Install tanks, Prepare left tank, Prepare left tank plumbing – Great Plains YP Fertilizer System User Manual

Page 3: Caution

Advertising
background image

Great Plains Mfg., Inc.

Installation Instructions

3

02/29/2008

407-197M

Install Tanks

This section installs most of the components of the 407-
122A kit.

!

CAUTION

High profile hazard - install the tanks on a calm day or in a
location protected from wind.

Prepare Left Tank

Refer to Figure 2
5.

The left tank and cradle is pre-assembled but does
not have an assembly part number. It is identified by
the mounting plate

orientation. With the sight tube

facing forward, the plate is on the bottom right

(inside).

6.

Remove and save the following parts:

Prepare Left Tank Plumbing

Refer to Figure 3 and Figure 4
Each tank has a shut-off/clean-out assembly (left

,

right

, and these are mirror images of each other).

The shut-off valve handles are to the inside (planter cen-
ter) with handles pointing to planter rear when valves are
open.

Qty

Call

Part

Description

4

803-027C NUT HEX 3/4-10 PLT

4

804-023C WASHER LOCK SPRING 3/4 PLT

2

806-050C U-BOLT 3/4-10 X 7 X 8 1/2

Figure 2

Left Tank, As Shipped

27087

2

U

D

F

B

L

R

1

115

114 110

1

2

110

114

115

Figure 3

Tank Fittings ID

99999

R

U

D

F

B

L

R

L

L

R

Advertising