Pump to starter relief valve hose, Starter hose to left wing boom – Great Plains YP Fertilizer System User Manual
Page 23

Great Plains Mfg., Inc.
Installation Instructions
23
02/29/2008
407-197M
Pump to Starter Relief Valve Hose
126. Select:
Refer to Figure 42
127. Route the hose from the outlet elbow of the pump
to the inlet adaptor
of the relief valve.
128. Secure the hose
to the relief valve with a clamp
.
129. At the pump end, allowing some slack, cut the hose
to length and secure it to the outlet elbow
clamp
.
Starter Hose to Left Wing Boom
130. Select:
Refer to Figure 43
131. Connect the hose
to the adaptor
at the outlet
tee of the relief valve assembly. Secure with clamp
.
132. Route the hose
to the elbow
and tee at the
center of the left wing boom.
133. Allowing a small amount of slack, cut hose to length
and secure with clamp
.
Qty
Call
Part
Description
-
990-082R HOSE 1 ID 200PSI EPDM
2
800-257C CLAMP WRM DRV #20SS (.81-1.75)
Figure 42
Pump to Starter Relief Valve
27113
3
2
3
2
Qty
Call
Part
Description
-
990-081R HOSE 3/4 ID 200PSI EPDM
2
800-257C CLAMP WRM DRV #20SS (.81-1.75)
Figure 43
Starter Relief Valve to Left Boom
27113
4