Install Starter Drop Lines

If your planter has fewer than 32 row units, some posi-
tions get caps instead of drop lines.

142. Raise the planter and install transport locks.

143. Lower the row units.

144. Select:

145. If not already installed on the nozzles, select:

Not all of the caps may be used.

Refer to Figure 48.
146. If the nozzle has no associated row unit, install a cap

.

147. At each nozzle connected to a row, route the hose

from the nozzle down to the row unit applicator (typi-
cally a tube on a seed firmer).

148. Connect the hose

end to the tube (not shown),

using a push-lok adaptor

.

149. Use a cable tie

(not shown) to secure the hose

as needed to the applicator structure. Allow slack for
row unit motion.

150. Allowing a small amount of slack, cut the hose to

length at the boom nozzle. The Figure notwithstand-
ing, do not loop the line or allow it to sag.

151. Connect the hose

end to the nozzle with an

adaptor

.

Qty

Call

Part

Description

-

990-109R TUBE NYLON 1/4OD X 062WL

16

832-042C NOZZLE SHUT OFF CAP W/ GASKET

32

830-383C CP 1/4 PUSH LOK POLY

32

800-303C CABLE TIE 2 DIA MIN - BLK

Qty

Call

Part

Description

32

800-367C AD PUSH 1/4TUBEX1/4MNPT

Figure 48