Assembly 13

12/10/2009

195-067Q

Two Outlet Kit

If the Two-Outlet Hydraulic Kit was ordered, install it now
(before the markers, as this kit contains items needed
when both 2-outlet and markers are installed).

Installation instructions are provided in a separate man-
ual with the Two-Outlet kit.

Markers

Markers are not factory-installed, due to vertical clear-
ance requirements during shipment. An installation
manual is provided, but does not include details for
installation where a Two-Outlet Kit is also present. If a
Two-Outlet kit is installed, observe these tips:

• The Marker/Fold valve mounts on the second valve

bracket.

• Use the longer bolts in the Two-Outlet kit to stack the

hose clamps. Place the clamp hold-down on the top
clamp.

• For consistency of operation, be sure to plumb the

Fold circuit to the forward ports of the Marker/Fold
valve, and plumb the Marker circuits to the rear.

Handle forward is then Transport operations (Fold),
and handle back is then Field operations (Marker).

Consult the drill Operator’s manual for setting initial
marker extension length, and the latest information on
chain length adjustment.