Troubleshooting – Great Plains CTA4000 HD Operator Manual User Manual

Page 55

Advertising
background image

2012-11-28

160-037M

Great Plains Manufacturing, Inc.

51

Troubleshooting

This chart primarily covers problems arising from
implement issues, although it does include a few cart
items.

Also consult the Troubleshooting chart for the cart.

Problem

Cause

Solution

Planting too little

Air leaks

Check hopper lids, meter seals, manifold caps
and seed hose connections. Adjust latch
and/or replace seals as needed.

Fan speed too low

See “Fan speed is monitored and reported
by the seed monitor, but is manually
controlled. The optimum rate depends on
the seed type and treatments. See “Fan
Speed Adjustment” in the cart Operator’s
Manual for further
information.Recommended Fan Speeds
” on
page 35.

Implement lift switch engaging too
high

See “Implement Lift Switch Adjustment” on
page 39.

Excessive field speed

Reduce speed

Excessive gaps between
implement passes

Adjust markers.

Actual field size is different

Verify field size.

Plugged seed hose

Clean out seed tube hose.

Remove excess slack in hoses.

Re-route hoses to avoid sharp bends.

Check that metering is actually stopping when
implement is raised. Adjust or replace
implement lift switch.

Plugged opener seed tube

Lift up implement, expose bottom of seed tube
and clean out.

Obstruction in meter or seed
tubes (foreign material or
uncleaned seed)

Clean meter and seed tube.

Planting too much

Meter setting too high

Re-check against chart & calibration.

Actual field size is different

Verify field size.

Excessive overlap or irregular
shaped field

Adjust marker.

Advertising