Nta-3010 installation, Nta30: install wsmbs – Great Plains NTA3510 Installation Instructions User Manual

Page 17

Advertising
background image

Great Plains Mfg., Inc.

Installation Instructions

17

10/29/2008

168-414M

NTA-3010 Installation

This installation requires one of the following kits:
168-404A

NTA3010-4875 (48 row, 7.5in)

168-405A

NTA3010-3610 (36 row,10in)

Additional installation information is found in the
DICKEY-john IntelliAg Air Cart Control Operator’s man-
ual.

Note: The DICKEY-john manual has only general har-

ness routing for the Great Plains air drills, and
some cable part numbers are slightly different from
those in the kits.

Continuing from step 8 on page 3.

Refer to Figure 35 and Figure 36

9.

Select four (4):

168-465D

DIST TOWER MODULE MOUNT PLATE

At each tower, remove the nuts

and lock washers

at the lower U-Bolt

, and mount the plate

.

Plate orientation is small holes to top, and
extensions to drill center.

NTA30: Install WSMBs

Start with the left tower (Tower 1).

10. Select one:

467981100S1

INTAG WSMB/FLW MNTR MODULE 18R

and two sets:

802-224C HHCS 1/4-20X1 1/4 GR5
804-006C WASHER LOCK SPRING 1/4 PLT
803-006C NUT HEX 1/4-20 PLT

Mount the WSMB

on the tower side of the plate

, with the mounting ears flush against the plate

and the connector ports facing down.

11. Repeat step 10 for the remaining towers

Figure 35

NTA3010 Tower Arrangement

28437

T1

T2

T3

T4

U

D

F

B

L

R

12

1

2

3

12

Figure 36: NTA30:

Module Mount

27058

12

39

14

16

15

3

2

1

39

14

16

15

39

12

Advertising