Boxes not emptying
evenly

Some boxes do not have same
number of feed cups between each
divider of bulkhead.

Load more material than required.
Re-distribute when re-loading.

Main box seed cup door setting

Set all doors the same, per seed size.

Seed plug(s) installed

Remove seed plug(s).

Meter or tube blocked

Clear blockage.

Press wheel or openers
plugging

Planting conditions too wet

Wait until drier weather.

Too much down pressure on openers

Reduce down pressure on openers
(page 21).

Backed up with drill in the ground

Clean out and check for damage.

Failed disc bearings

Replace disc bearings.

Scraper worn or damaged

Replace scraper.

Feed cup sprockets
locked up or twisted feed
cup drive shaft

Foreign matter lodged in one or more
feed cup sprockets

Clean out feed cup sprockets. Use clean
seed.

Dried liquid insecticide inside feed
cups

Remove build up by disassembling each feed
cup and scraping foreign substance from turn
surfaces.

Small seeds box not
emptying evenly

Aw~usueg g+divider (Option) not seˇ!
evenly

Move adjustable divider to create more
volume in areas that run out first.

Chain fouling

Debris in retainer clip

Be sure retainer clip is facing opposite way of
chain travel (page 31).

Acremeter inaccurate

Excess wheel slippage

Check frame height. If correct, solution may
be to wait for drier conditions.

Passes misaligned

Check that planting passes are not leaving
gaps (under-reporting area) or causing
overlap (over-reporting area).

Wheel slippage is varying from
nominal

If variance is consistent, develop a correction
factor for your conditions.

Check that acremeter is for your drill.

Activate display. Lower left corner must be:
3P500: 928 revs/ac or 2293.1 revs/ha
3P500V: 928 revs/ac or 2293.1 revs/ha
3P600: 786 revs/ac or 1942.2 revs/ha
Contact dealer if otherwise.

Acremeter battery failing

Replace acremeter (page 16). Unit is sealed
and battery is not replaceable.