Vansco Electronic Monitor Technical Specifications

Fan RPM

Fan RPM is displayed when the selector switch is set to FAN.

The RPM range is 0-9990 RPM with a resolution of 10 RPM.

The fan RPM is continuously monitored for alarm purposes.

The alarm trips when the fan speed falls below the user variable low alarm set point or goes above

the user variable high alarm set point

The factory programmed low alarm point is 3000 RPM. The user adjustable range is between 0 and

the high set point. Low alarm point should be set at 2000 RPM.

The factory programmed high alarm point is 6500 RPM. The user adjustable range is between 0 and

9900 RPM. Reset the high alarm point at 5000 RPM.

The factory programmed pulses per revolution is 1. Reset pulses per revolution to 3.

Response time to an alarm condition is 1 second maximum.

Shaft RPM

Two shaft speeds, Front and Rear are monitored. Shaft speeds are displayed when the rotary switch is set
to the appropriate position.

The operator may disable unwanted shaft inputs.

The input signal is from a reed switch.

All shaft speeds are continuously monitored for alarm purposes.

An alarm will be generated whenever there is more than 15 seconds between reed switch hits.

Shaft alarm generation will be delayed by 30 seconds if ground speed is below 2 MPH. This delay is

intended to reduce nuisance alarms when turning on headlands.

The monitors are factory programmed with the bins and shafts disabled.

Set both shafts for 2 pulses per revolution.

Bin Level Indication

Two bin levels are monitored; Front and Rear

The bins are pressurized to 20" - 30" H

2

0

The input signal is a Vansco 77000 series optical Type Full Bin Detector

To minimize nuisance alarms, there is a 15 second delay before the bin alarm is displayed

When a shaft input is disabled, the corresponding bin level input is also disabled.

The monitors are factory programmed with bins and shafts disabled.

Standard Parameter Settings for 2250 Air Drill Systems Monitor

Function

Display

Value

Fan Speed Pulses Per Revolution

PLSE

3

Fan Low Speed Alarm

FAnL

2000

Fan High Speed Alarm

FAnH

5000

Ground Speed Pulses Per Mile (average drills)

PLSE

34’ Drill 2213

45’ Drill 2900

Front Shaft Pulses Per Revolution

PLSE

2

Rear Shaft Pulses Per Revolution

PLSE

2

Flow or Blockage Module Complement (for drills without blockage sensing)

xx--

xx00

Flow or Blockage Module Type Value

tY--

tY00

Implement Width

Lnth

34’ Drill 34.0

45’ Drill 45.0

English or Metric Units

unit

Eng

NOTE: Monitor is shipped from the factory with all sensors disabled or set to null values. Correct values must be set on monitor
prior to initial use, based on actual unit width.