Troubleshooting system memory, See "troubleshooting system – Dell POWEREDGE 2950 User Manual

Page 120

Advertising
background image

120

Troubleshooting Your System

Action

CAUTION:

Only trained service technicians are authorized to remove the system cover and access any of the

components inside the system. Before performing any procedure, see your Product Information Guide for
complete information about safety precautions, working inside the computer and protecting against electrostatic
discharge.

1 Run the appropriate diagnostic test. See "Using Server Administrator Diagnostics" on page 131.
2 Open the system. See "Opening and Closing the System" on page 54.

CAUTION:

The cooling fans are hot-pluggable. To maintain proper cooling while the system is on, only replace

one fan at a time.

3 Locate the faulty fan indicated by the LCD display or diagnostic software. For the identification

number of each fan, see Figure 3-9.

4 Ensure that the faulty fan's power cable is firmly attached to the fan power connector. See "System

Fans" on page 65.

NOTE:

Wait 30 seconds for the system to recognize the fan and determine whether it is working properly.

5 If the problem is not resolved, install a new fan. See "System Fans" on page 65.

If the replacement fan is working properly, close the system. See "Opening and Closing the System" on
page 54.

If the replacement fan does not operate, see "Getting Help" on page 147.

Troubleshooting System Memory

Problem

Faulty memory module.

Faulty system board.

Front-panel status LCD indicates a problem with system memory.

Action

CAUTION:

Only trained service technicians are authorized to remove the system cover and access any of the

components inside the system. Before performing any procedure, see your Product Information Guide for
complete information about safety precautions, working inside the computer and protecting against electrostatic
discharge.

1 Run the appropriate online diagnostic test. See "Using Server Administrator Diagnostics" on page 131.
2 Turn on the system and attached peripherals.

If an error message does not appear, continue to the next step.

If an error messages appears, go to step 11.

Book.book Page 120 Friday, February 3, 2006 11:09 AM