About Your System

33

ROM bad checksum = address

Expansion card improperly installed or
faulty.

Reseat the expansion card(s). Ensure
that all appropriate cables are securely
connected to the expansion card(s). If
the problem persists, see
"Troubleshooting Expansion Cards" on
page 127.

Sector not found

Seek error

Seek operation failed

Faulty diskette or hard drive.

See "Troubleshooting a Diskette Drive"
on page 121, "T
roubleshooting a USB
Device" on page 115, or
"Troubleshooting a Hard Drive" on
page 124 for the appropriate drive(s)
installed in your system.

Shutdown failure

Shutdown test failure.

See "Troubleshooting System Memory"
on page 120.

The amount of system

memory has changed

Memory has been added or removed
or a memory module may be faulty.

If memory has been added or removed,
this message is informative and can be
ignored. If memory has not been added
or removed, check the SEL to determine
if single-bit or multi-bit errors were
detected and replace the faulty memory
module. See "Troubleshooting System
Memory" on page 120.

Time-of-day clock stopped

Faulty battery or faulty chip.

See "Troubleshooting the System
Battery" on page 118.

The following DIMM pair is

not compatible with the

memory controller: DIMM x

and DIMM y

The specified DIMM(s) are
incompatible with the system.

Ensure that only Dell-qualified memory
is used. Dell recommends purchasing
memory upgrade kits directly from
www.dell.com or your Dell sales agent to
ensure compatibility.

The following DIMMs are

not compatible: DIMM x and

DIMM y

The specified DIMM(s) are
incompatible with the system.

Ensure that only ECC FBD1 memory is
used. Dell recommends purchasing
memory upgrade kits directly from
www.dell.com or your Dell sales agent to
ensure compatibility.

Time-of-day not set -

please run SETUP program

Incorrect Time or Date settings; faulty
system battery.

Check the Time and Date settings. See
"Using the System Setup Program" on
page 37. If the problem persists, r
eplace
the system battery. See "System Battery"
on page 96.

Table 1-7.

System Messages (continued)

Message

Causes

Corrective Actions

Book.book Page 33 Friday, February 3, 2006 11:09 AM