Clearance to combustibles, Mantels, Hearth – Vermont Casting DV580 User Manual

Page 6

Advertising
background image

6

DV360/580 Series Direct Vent Gas Fireplace

20010667

Clearance to Combustibles

Top of unit to ceiling ................................. 36” (914 mm)
Front of unit to combustibles ................... 36” (914 mm)
Appliance

Top of standoff ....................................... 0” (0 mm)

Bottom ..................................................... 0” (0 mm)

Side ......................................................... 0” (0 mm)

Back ........................................................ 0” (0 mm)

Venting
Concentric sections of DV Vent ................... 1” (25 mm)
Nonconcentric sections of DV Vent

Sides and bottom .................................. 1” (25 mm)

Top ........................................................ 2” (51 mm)

Mantels

The height that a combustible mantel is fitted above the
fireplace is dependent on the depth of the mantel. This
also applies to the distance between the mantel leg (if
fitted) and the fireplace.
For the correct mounting height and widths, refer to
Figures 4a, 4b and the Mantel Chart below.
The distances and reference points are not affected by
the fitting of a bay window front trim kit.
Noncombustible mantels and legs may be installed at
any height and width around the appliance. When using
paint or lacquer, it must be heat resistant to prevent
discoloration.

A B C D E

V

W

X

Y

Z

Fireplace

CFM146

DV Mantel Chart

7/5/01 sta

Maintain minimum

3/4” (19 mm) clear-

ance to combustibles

Louvre Assembly

top

Top of Combustion

Chamber

CFM146

Bottom of Door Trim

Mantel Chart

Mantel Shelf

Mantel from Top

Ref. or Breast Plate

Ref. of Comb. Chamber

Depth

V

10” (254 mm)

A

19” (483 mm)

W

8” (203 mm)

B

17” (432 mm)

X

6” (152 mm)

C

15” (381 mm)

Y

4” (101 mm)

D

13” (330 mm)

Z

2” (51 mm)

E

11” (279 mm)

Fig. 4a Combustible mantel minimum installation.

Hearth

A hearth is not mandatory, but is recommended for
aesthetic purposes. We recommend a noncombustible
hearth which projects out 12” (305 mm) or more from
the front of the fireplace.
Cold climate installation recommendation:

When installing this unit against a non-in-
sulated exterior wall or chase, it is manda-
tory that the outer walls be insulated to
conform to applicable insulation codes.

J

F

G

H

I

Mantel

Leg

CFM164a

Mantel Leg Chart

06/22/01 sta

CFM170

DV Builder Front

View

O

N

M

L

K

Black

Surround

Face

CFM164a

Side of

Combustion Chamber

CFM170

Mantel

Mantel Leg from Side

Ref.

Leg Depth

Ref.

of Comb. Opening

F

10” (254 mm)

K

11¹⁄₂” (292 mm)

G

8” (203 mm)

L

9¹⁄₂” (241 mm)

H

6” (152 mm)

M

7¹⁄₂” (191 mm)

I

4” (101 mm)

N

5¹⁄₂” (140 mm)

J

2” (51 mm)

O

3¹⁄₂” (89 mm)

Fig. 4b Combustible mantel leg minimum installation.