Framing and finishing, Final finishing, Gas specifications – Vermont Casting DV580 User Manual

Page 7: Gas inlet and manifold pressures

Advertising
background image

7

DV360/580 Series Direct Vent Gas Fireplace

20010667

Framing And Finishing

Check fireplace to make sure it is levelled
and properly positioned.

To mount the appliance: Choose the location.
DV360 (Fig. 5)
1. This unit comes with four (4) flanges pre-mounted

on both sides of the fireplace to allow two different
drywall thicknesses to be used. Flange “A” is for 1/2”
drywall while flange “B“ is for 5/8” drywall.

2. Bend the desired flanges out 90° on both sides of

the fireplace. Slide the fireplace into the framed
opening until the flanges contact the front surfaces
of the framing. Level the unit and secure it firmly in
place.

A

B

FP1539

flange location

12/04

Flange

Drywall

Position

Depth

A

1/2” / 13 mm

B

5/8” / 16 mm

Flange Location for

Desired Drywall Depth

FP1539

Fig. 5 Drywall flange location for DV360.

DV580 (Fig. 5a)
1. Nailing flanges are supplied with the fireplace (found

on the fireplace hearth). To level the box and secure
it firmly in place, remove the nailing flanges from
the hearth and install at the sides of the fireplace as
shown in Figure 5a.

2. Screw through the slotted holes in the drywall strip

and into pre-drilled holes in fireplace side. Measure
from face of fireplace to the face of the drywall strip
to confirm the final depth.

Final Finishing

Noncombustible materials such as brick or tile can be
extended over the edges of the face of the fireplace.
Do not cover the window frame assembly, any vent,
louvre assembly top or louvre assembly bottom.
If
a Trim Kit is to be installed, brick and tile will have to be
installed flush with the side of this appliance.

FP1023

side nailing flange

1/27/00 djt

A

B

C

Adjustable Drywall Strip

(Nailing Flange)

Flange

Drywall

Position

Depth

A

1/2” / 13 mm

B

5/8” / 16 mm

C

3/4” / 19 mm

Adjustable

1/2”, 5/8” & 3/4”

Spacing

FP1023

Fig. 5a Adjustable drywall strip (nailing flange) for DV580.

DV360 / DV580

Certified To

ANSI Z21.88-2005 / CSA 2.33-2005

Vented Gas Fireplace Heater

For units:
GFDN4L2, GFDE4L2, GFDI4L2, GFDL4L2
GFDN4P0, GFDE4P0, GFDI4P0

Gas Specifications

MAX.

MIN.

GAS

INPUT INPUT

MODEL

FUEL

CONTROL

B.T.U.H B.T.U.H.

DV360RN

Natural Gas

Millivolt Hi/Lo

30,000

18,500

DV360RP

Propane

Millivolt Hi/Lo

30,000

17,000

DV360EN

Natural Gas

24 Volt Hi/Lo

30,000

18,500

DV360EP

Propane

24 Volt Hi/Lo

30,000

20,000

DV360RFN Natural Gas Comfort Control 30,000

20,000

DV360RFP

Propane

Comfort Control 30,000

21,000

DV580RN

Natural Gas

Millivolt Hi/Lo

38,000

26,500

DV580RP

Propane

Millivolt Hi/Lo

38,000

27,000

DV580EN

Natural Gas

24 Volt Hi/Lo

38,000

26,500

DV580EP

Propane

24 Volt Hi/Lo

38,000

27,000

DV580RFN Natural Gas Comfort Control 38,000

26,500

DV580RFP

Propane

Comfort Control 38,000

27,000

Gas Inlet and Manifold Pressures

Natural

LP (Propane)

Minimum Inlet Pressure

5.5” w.c.

11.0” w.c.

Maximum Inlet Pressure

14.0” w.c.

14.0” w.c.

Manifold Pressure

3.5” w.c.

10.0” w.c.

Advertising