Lcd status messages update – Dell POWEREDGE 1950 User Manual

Page 15

Advertising
background image

Information Update

15

LCD Status Messages Update

Table 1-2 lists updates to the LCD status messages that can occur on
the PowerEdge 1950 III system and the probable cause for each message.
The LCD messages refer to events recorded in the system event log (SEL).
For information on the SEL and configuring system management settings,
see your systems management software documentation.

Warning: The

installed memory

configuration is

not optimal. For

more information on

valid memory

configurations,

please see the

system

documentation on

the technical

support web site.

Invalid memory
configuration. The system
runs but with reduced
functionality.

Ensure that the memory
modules are installed in a
valid configuration. See
"General Memory Module
Installation Guidelines"
in the

Hardware Owner’s

Manual. If the problem
persists, see
"Troubleshooting System
Memory" in the

Hardware

Owner’s Manual.

Write fault

Write fault on

selected drive

Faulty USB device, USB
medium, optical drive
assembly, hard drive, or
hard-drive subsystem.

Replace the faulty media.
Reseat the USB device or
USB cable. For hard drive
problems, see
"Troubleshooting a Hard
Drive" in the

Hardware

Owner’s Manual.

Table 1-1.

System Messages (continued)

Message

Causes

Corrective Actions

Advertising