Dell POWEREDGE 1950 User Manual

Page 16

Advertising
background image

16

Information Update

Table 1-2.

LCD Status Messages

Code

Text

Causes

Corrective Actions

N/A

SYSTEM NAME

A 62-character
string that can be
defined by the user
in the System Setup
program.

The SYSTEM NAME
is displayed under
the following
conditions:

• The system is

powered on.

• The power is off

and active errors
are displayed.

This message is for
information only.

You can change the
system ID and
name in the System
Setup program. See
"Using the System
Setup Program" in
the

Hardware

Owner’s Manual.

E1000

FAILSAFE, Call

Support

Check the system
event log for critical
failure events.

See "Getting Help"
in the

Hardware

Owner’s Manual.

E1118

CPU Temp

Interface

The BMC is unable
to determine
the CPU(s)
temperature status.
Consequently, the
BMC increases
the CPU fan speed
to maximum
as a precautionary
measure.

Turn off power to
the system and
restart the system.
If the problem
persists, see
"Getting Help"
in the

Hardware

Owner’s Manual.

E1211

ROMB Batt

RAID battery is
either missing, bad,
or unable to
recharge due to
thermal issues.

Reseat the RAID
battery connector.
See the "RAID
Battery" and see
"Troubleshooting
System Cooling
Problems" in the
Hardware Owner’s
Manual.

Advertising