System messages, Table 2, Describe the indicators on the nic – Dell PowerEdge 1850 User Manual

Page 16

Advertising
background image

 

Table 2-6. NIC Indicators 

 

System Messages

System messages appear on the screen during system boot to notify you of a possible problem with the system.

Table 2

-7

lists the system messages that can

occur and the probable cause and corrective action for each message.

 

Table 2-7. System Messages 

 

Link
indicator

 

Activity
indicator

 

Description

Off

Off

The NIC is not connected to the network or the NIC is disabled in the System Setup screen. See "Using the System Setup
Program" in the User's Guide.

Green

Off

Indicates that the network adapter is connected to a valid link partner on the network, but data is not currently being sent
or received.

Green

Blinking amber

Indicates that network data is being sent or received.

NOTE:

If you receive a system message that is not listed in

Table 2

-7

, check the documentation for the application that is running when the message

appears or the operating system's documentation for an explanation of the message and recommended action.

 

Message

 

Causes

 

Corrective Actions

Alert! Redundant memory disabled!

Memory configuration does not support

redundant memory.

The current memory
configuration does not
support redundant memory.

Install a memory configuration that supports redundant memory (spare bank
feature). See "

General Memory Module Installation Guidelines

" in "Installing

System Components."

Disable the Redundant Memory option in the System Setup program. See
"Using the System Setup Program" in your User's Guide.

Amount of available memory limited to

245MB!

OS Install Mode is enabled in
the System Setup program.

Disable OS Install Mode in the System Setup program. See "Using the System
Setup Program" in your User's Guide.

Attempting to update Remote

Configuration. Please wait....

Remote Configuration is in
progress

Wait until the process is complete.

BIOS Update Attempt Failed

BIOS remote update failed

Retry update

Caution! NVRAM_CLR jumper is installed

on system board.

NVRAM_CLR jumper is
installed.

Remove the NVRAM_CLR jumper. See

Figure A

-2

for the jumper location.

CD-ROM drive not found

Improperly connected or
missing CD drive.

If no optical drive is installed, disable the IDE controller. See "Using the System
Setup Program" in the User's Guide.

If an optical drive is installed, see "

Troubleshooting an Optical Drive

" in

"Troubleshooting Your System."

CPUs with different cache sizes

detected.

Mismatched processors are
installed.

Install a correct version of the microprocessor so that both microprocessors
have the same cache size. See "

Replacing the Processor

" in "Installing System

Components."

Decreasing available memory

Faulty or improperly installed
memory modules.

Ensure that all memory modules are properly installed. See "

Troubleshooting

System Memory

," in "Troubleshooting Your System."

Diskette drive 0 seek failure

Incorrect configuration
settings in System Setup
program.

Run the System Setup program to correct the settings. See "Using the System
Setup Program" in your User's Guide.

Faulty or improperly installed
diskette, loose diskette drive
or optical drive interface
cable, or loose power cable.

Replace the diskette. Ensure that the diskette drive and optical drive cables are
properly connected. See "

Troubleshooting a Diskette Drive

," and

"

Troubleshooting an Optical Drive

," in "Troubleshooting Your System."

Diskette read failure

Faulty or improperly inserted
diskette.

Replace the diskette.

Diskette subsystem reset failed

Faulty diskette drive or optical
drive controller.

Ensure that the diskette drive and optical drive cables are properly connected.
See "

Troubleshooting a Diskette Drive

," "

Troubleshooting an Optical Drive

," in

"Troubleshooting Your System." If the problem persists, see "

Getting Help

."

Drive not ready

Diskette missing or improperly
inserted in diskette drive.

Reinsert or replace the diskette.

Embedded RAID error

An error has been generated
by the firmware used by the
optional integrated RAID
controller (when available)

Update the RAID firmware using the Dell Support website at support.dell.com.

Embedded RAID firmware is not present

The firmware used by the
optional integrated RAID
controller (when available) is

Restore the RAID firmware using the Dell Support website at support.dell.com.

Advertising